Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Clock Mode

Configuring the Clock Mode

Context

A POS interface supports the following clock modes:

  • master: uses the internal clock signal.
  • slave: uses the line clock signal.
  • system: uses the MPU clock signal.

When the POS interfaces of the router and a remote device are directly connected, set the clock mode of one end to master and that of the peer end to slave. When the POS interface of a device is connected to the SONET or SDH network, set the clock mode of the POS interface to slave because the SONET or SDH network clock has a higher accuracy than the POS interface.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface pos interface-number

    The POS interface view is displayed.

  3. Run clock { master | slave | system }

    The clock mode is set for the POS interface.

    By default, the clock mode of a POS interface is slave.