CLI-based Configuration Guide - IP Multicast

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the basic concepts, configuration procedures, and configuration examples of the interfaces supported by the device.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Sending IGMP Query Messages upon Topology Changes

Sending IGMP Query Messages upon Topology Changes

Context

When a Layer 2 network topology changes, the forwarding path of multicast packets may change. When a fault occurs on a link, the router sends IGMP Query messages and the multicast members reply with IGMP Report messages. The router then updates information about multicast member ports based on the IGMP Report messages. In this manner, multicast packets can be switched to new forwarding paths in time.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run igmp-snooping send-query enable

    IGMP Query messages are sent upon topology changes.

    By default, the router is disabled from sending IGMP Query messages upon topology changes.

    This command enables the router to send IGMP Query messages (the source IP address is 192.168.0.1 by default) upon topology changes, and update information about multicast member ports in time, so that multicast packets to the downstream members are interrupted only for a short period.

  3. (Optional) Run igmp-snooping send-query source-address ip-address

    The source IP address of an IGMP General Query message is configured.

    By default, the source IP address of an IGMP General Query message sent upon topology changes is 192.168.0.1. If this IP address is used by other devices on the network, you can use this command to set another IP address.