CLI-based Configuration Guide - Network Management and Monitoring

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the basic concepts, configuration procedures, and configuration examples in different application scenarios of the network management feature supported by the device.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
TCP Test

TCP Test

The NQA TCP test measures the time taken to set up a TCP connection between an NQA client and a TCP server through the three-way handshake.

The TCP test process is as follows:

  1. The source (RouterA) sends a TCP SYN packet to the destination (RouterB) to set up a TCP connection.

  2. The destination receives the TCP SYN packet and responds with a TCP SYN-ACK packet.

  3. The source receives the SYN-ACK packet and sends an ACK packet to the destination. The connection is now established and the source can calculate the time taken.

Figure 7-10  TCP test scenario

Router A calculates the time taken to set up the TCP connection with router B by subtracting the time router A sends the TCP SYN packet to the time router A receives the TCP SYN ACK packet. The test result reflects TCP performance on the network.

Frequent TCP tests will consume too many resources and affect running services on the device.

TCP test results and historical records are collected in test instances. You can run commands to view the test results and historical records.