CLI-based Configuration Guide - Network Management and Monitoring

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the basic concepts, configuration procedures, and configuration examples in different application scenarios of the network management feature supported by the device.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the NQA Client to Send Traps When a Probe Fails

Configuring the NQA Client to Send Traps When a Probe Fails

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run nqa test-instance admin-name test-name

    The NQA view is displayed.

  3. Run send-trap probefailure

    The NQA client is configured to send traps when a probe fails.

    By default, the NQA client sends no trap when a probe fails.

  4. Run probe-failtimes times

    The threshold on the traps sent after the probe fails is configured, The threshold specifies maximum number of continuous probe failures for the NQA test instance.

    By default, a trap is sent for each probe failure.