CLI-based Configuration Guide - Reliability

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides guidance for configuring reliability services, including interface backup, BFD, VRRP, and EFM.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Association Between EFM and BFD

Configuring Association Between EFM and BFD

Context

For details on the principle and usage scenarios of association between EFM and BFD, see Fault Information Advertisement Between EFM and Other Modules.

Association between EFM and BFD is bidirectional:
  • If EFM detects a link fault, it will notify BFD of the fault.

  • If BFD detects a link fault, it will notify EFM of the fault.

The following types of BFD sessions can be used:
  • Static BFD for LSP (LDP, TE, TE LSP, static LSP, and VLL PW) sessions (a PST is required)

  • BFD for IP sessions (no PST is required)

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run oam-mgr

    The OAM management view is displayed.

  3. Run the following commands as required.

    • Unidirectional association

      Run the oam-bind ingress efm interface interface-type interface-number egress bfd-session bfd-session-id command to configure EFM to notify BFD of faults.

      Run the oam-bind ingress bfd-session bfd-session-id egress efm interface interface-type interface-number command to configure BFD to notify EFM of faults.

    • Bidirectional association

      Run the oam-bind efm interface interface-type interface-number bfd-session bfd-session-id command to configure EFM and BFD to notify each other of faults.

    NOTE:

    The functions of two commands used to configure association functions in opposite directions are the same as those of the command used to configure the bidirectional association function.

    If the oam-bind efm interface interface-type interface-number bfd-session bfd-session-id command is run, the oam-bind ingress efm interface interface-type interface-number egress bfd-session bfd-session-id and oam-bind ingress bfd-session bfd-session-id egress efm interface interface-type interface-number commands will be displayed in the configuration file.

Translation