No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CLI-based Configuration Guide - Reliability

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides guidance for configuring reliability services, including interface backup, BFD, VRRP, and EFM.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Adjusting the BFD Detection Time

Adjusting the BFD Detection Time

Context

When you set up a BFD session, you can adjust the minimum interval for sending BFD packets, minimum interval for receiving BFD packets, and local detection multiplier based on the network situation and performance requirements.

To reduce usage of system resources, when a BFD session is detected in Down state, the system adjusts the minimum interval for receiving BFD packets and the minimum interval for sending BFD packets to random values greater than 1000 ms. When the BFD session becomes Up, the configured intervals are restored.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run bfd session-name

    The BFD session view is displayed.

  3. Run min-tx-interval interval

    The minimum interval for sending BFD packets is set.

    By default, the minimum interval for sending BFD packets is 1000 ms.

  4. Run min-rx-interval interval

    The minimum interval for receiving BFD packets is set.

    NOTE:

    To reduce usage of system resources, when a BFD session is detected in Down state, the system adjusts the minimum interval for receiving BFD packets and the minimum interval for sending BFD packets to random values greater than 1000 ms. When the BFD session becomes Up, the configured intervals are restored.

    By default, the minimum interval for receiving BFD packets is 1000 ms.

  5. Run detect-multiplier multiplier

    The local detection multiplier is set.

    By default, the local detection multiplier is 3.

Translation
Download
Updated: 2019-03-06

Document ID: EDOC1100069338

Views: 14200

Downloads: 42

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next