Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Power Grid Object Parameter Plan

Power Grid Object Parameter Plan

Power grid objects include transformer districts, power supply lines, transformer substations, and transformers, and power grid object profiles of the EEM involve transformer substations, lines, and transformer districts. Different parameters are configured for different power grid objects, as described in Table 6-18.
Table 6-18  Power grid object parameter plan

Item

Parameter

Description

Transformer substation

Grid Type

The value is Substation, Feeder, or DT. Select the value based on the created power grid object.

Name

Name of a transformer substation, which can be user-defined. It can contain a maximum of 128 letters and digits, excluding special characters. Names of power grid objects of the same parent node must be unique.

Grid No.

The value is composed of the input 7-digit number. Numbers of power grid objects in the EEM are unique.

Voltage Code

Select the value based on the actual power grid environment. The value can be 11kV, 220V, 415V, 33kV, or 132kV.

Parent Grid Name

Name of a power grid object of the parent node.

Organization Name

Name of an organization that a transformer substation belongs to.

Feeder

Grid Type

The value is Substation, Feeder, or DT. Select the value based on the created power grid object.

Name

Name of a line, which can be user-defined. It can contain a maximum of 128 letters and digits, excluding special characters. Names of power grid objects of the same parent node must be unique.

Grid No.

The value is composed of the input 7-digit number. Numbers of power grid objects in the EEM are unique.

Voltage Code

Select the value based on the actual power grid environment. The value can be 11kV, 220V, 415V, 33kV, or 132kV.

Parent Grid Name

Name of a power grid object of the parent node.

Organization Name

Name of an organization that a transformer substation belongs to.

Transformer district

Grid Type

The value is Substation, Feeder, or DT. Select the value based on the created power grid object. DT refers to the transformer district.

Name

Name of a transformer district, which can be user-defined. It can contain a maximum of 128 letters and digits, excluding special characters. Names of power grid objects of the same parent node must be unique.

Grid No.

The value is composed of the input 10-digit number. Numbers of power grid objects in the EEM are unique.

Capacity

Capacity of a transformer district, that is, maximum number of connected terminals.

Installation Address

Position of a transformer district.

Public Or Private Flag

Power distribution flag, which can be PUB or PRI. PUB indicates the public transformer substation and PRI indicates the private transformer substation.

Parent Grid Name

Name of a power grid object of the parent node.

Organization Name

Name of an organization that a transformer substation belongs to.