Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Discovering Devices

Discovering Devices

  1. Discover switches.

    1. Choose Network > Physical Resource > Device Management from the main menu.

    2. Select Auto Discovery from the Device Discovery drop-down list box.

    3. Set the related parameters based on the prepared data (the user name and password are openlab and Huawei@123 for all protocols), and click Start.

    4. Select all devices and click Add to add the devices to the Agile Controller-DCN. Click Confirm.

    5. After the devices are added, use Telnet to check whether connections to the devices are set up. The following uses TOR2 as an example.

    6. Repeat the preceding steps to discover and add TOR3.

  2. Discover firewalls.

    1. The procedure for discovering firewalls is similar to that for discovering CE switches. Note that the default NETCONF port is 830 on firewalls and 22 on CE switches. If the default NETCONF port has been changed on firewalls, you need to use the actual port to discover the firewalls.

    2. After the firewalls are added, run the display manager-user online-user command to check the link setup status.

      NOTE:

      The southbound address of the Agile Controller-DCN must be able to communicate with device addresses for the Agile Controller-DCN to manage devices. If the device discovery fails, check the network connectivity between the southbound address of the Agile Controller-DCN and the switch address and check whether the SNMP and NETCONF configurations are correct.