Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Changing the Database Password of the Analyzer

(Optional) Changing the Database Password of the Analyzer

This section describes how to change the database password of the eLog analyzer.

Prerequisites

  • If the password of the commonuser of the database changes, you must change the password of the database used by the eLog accordingly.
  • The analyzer has been stopped. For details, see Stopping the Analyzer or Collector.
  • The server on which security hardening is performed before delivery has the remote root connection function disabled. Therefore, the connection must be through the iBMC port or the mouse and keyboard. According to live network requirements, you can enable the remote root connection function as described in How to Enable or Disable Root Remote Connection. However, enabling this function may cause security risks. After completing installation operations, disable this function immediately.

Procedure

  1. Log in to the analyzer server as the root user.
  2. Right-click the desktop and choose Open in Terminal from the shortcut menu to access the CLI.
  3. Run the cd software-installation-path/engineering/tools command to access the directory.

    The default directory is /opt/huawei/LogCenter/engineering/tools.

  4. Run the ./config_network.sh command. Change the database password as prompted. After that, the database automatically restarts.

    NOTE:

    The default database password is Changeme123.

    LogServer:~ # cd /opt/huawei/LogCenter/engineering/tools
    LogServer:/opt/huawei/LogCenter/engineering/tools # ./config_network.sh
    Which operation do you want to execute?[1-7]
    1) Change the IP address.  5) Modify the database.
    2) Delete the IP address.  6) Change the web port.
    3) Set the gateway.	   7) Exit
    4) Configure DNS.
    #? 5
    Which operation do you want to execute?
    1) Change the database user password.    3)Exit
    2) Change the commonuser port.  
    #? 1
    Info: Start to change the database user password.
    Info: Input user name: commonuser            //for example,commonuser
    Info: Enter the old password:
    Info: Successed in logging mysql database.
    Info: Enter the new password:
    Enter the new password again:
    Info: Modification succeeded,and the services will be restarted.
    Info: Change mysql success