Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Connection Method 2: Use the Mouse and Keyboard to Directly Connect to the Server

Connection Method 2: Use the Mouse and Keyboard to Directly Connect to the Server

When you use the mouse and keyboard to install the operating system, only the installation CD-ROM (not the installation image file) applies. If you have the installation image file but not the installation CD-ROM, use connection method 1.

Setting a Server RAID

First, you need to set a RAID for it. The applicable RAID type varies with the actual configuration of the server. This section provides an example for configuring RAID1 and RAID6 for 2288H V5 server.

Context
Recommended configuration order (distributed deployment scenario):
  1. Two rear disks are grouped as RAID1.
  2. If front disks are available, they are grouped as RAID6, with one of them as the hot spare disk.
Recommended configuration order (centralized deployment scenario):
  1. Two back disks are grouped as RAID1.
  2. One front disk is configured as the public hot spare disk.
  3. Two front disks are grouped as RAID1, and no separate hot spare disk is configured.
  4. Nine front disks are grouped as RAID6, and no separate hot spare disk is configured.
(Optional) Deleting Useless RAID Groups

If there are useless RAID groups on the server, you can delete them by referring to this scenario.

  1. Restart the server using the iBMC remote virtual console. When the following page is displayed, press F11.

  2. Enter the password to access the configuration page.

    The initial password is Admin@9000.

  3. Press arrow keys to select DeviceManager and press Enter.

  4. Press arrow keys to select AVAGO MegaRAID... and press Enter.

  5. Select Main Menu and press Enter.

  6. Press arrow keys to select Virtual Drive Management and press Enter.

  7. Select the RAID group to be deleted and press Enter.

  8. Select Operation and press Enter.

  9. Press arrow keys to select Delete Virtual Drive and press Enter.

  10. Press arrow keys to select Go and press Enter.

  11. Press Enter and set Confirm to Enabled. Press arrow keys to select Yes and press Enter.

  12. Select OK and press Enter.

  13. The page is automatically displayed, indicating that the selected RAID group has been deleted.

  14. Press Esc to return to the previous menu. Configure all RAID groups by referring to other RAID configuration methods.
Configuring RAID1
  1. Restart the server using the iBMC remote virtual console. When the following page is displayed, press F11.

  2. Enter the password to access the configuration page.

    The initial password is Admin@9000.

  3. Press arrow keys to select DeviceManager and press Enter.

  4. Press arrow keys to select AVAGO MegaRAID... and press Enter.

  5. Select Main Menu and press Enter.

  6. Select Configuration Management and press Enter.

  7. Select Create Virtual Drive and press Enter.

  8. Press arrow keys to Select RAID Level and press Enter.

  9. Select RAID1 and press Enter.

  10. Press arrow keys to Select Drives and press Enter.

  11. Press arrow keys to select the disks to be added to the RAID group. Press Enter and set the disk state to Enabled. Set other disks that will be added to the RAID group to Enabled.

  12. Press down arrow keys to select Apply Changes and press Enter.

  13. Select OK and press Enter.

  14. Press arrow keys to select Save Configuration and press Enter.

  15. Press Enter and set Confirm to Enabled. Press arrow keys to select Yes and press Enter.

  16. Select OK and press Enter.

  17. Repeat the preceding steps until you complete related settings for RAID1. Configure other RAID groups by referring to other sheets. Repeat the preceding steps to configure other RAID groups. After all configurations are complete, restart the server.
Configuring RAID6
  1. Restart the server using the iBMC remote virtual console. When the following page is displayed, press F11.

  2. Enter the password to access the configuration page.

    The initial password is Admin@9000.

  3. Press arrow keys to select DeviceManager and press Enter.

  4. Press arrow keys to select AVAGO MegaRAID... and press Enter.

  5. Select Main Menu and press Enter.

  6. Select Configuration Management and press Enter.

  7. Select Create Virtual Drive and press Enter.

  8. Press arrow keys to Select RAID Level and press Enter.

  9. Select RAID6 and press Enter.

  10. Press arrow keys to Select Drives and press Enter.

  11. Press arrow keys to select the disks to be added to the RAID group. Press Enter and set the disk state to Enabled. Set other disks that will be added to the RAID group to Enabled.

  12. Press down arrow keys to select Apply Changes and press Enter.

  13. Select OK and press Enter.

  14. Press arrow keys to select Save Configuration and press Enter.

  15. Press Enter and set Confirm to Enabled. Press arrow keys to select Yes and press Enter.

  16. Select OK and press Enter.

  17. Repeat the preceding steps until you complete related settings for RAID6. Configure other RAID groups by referring to other sheets. After all configurations are complete, restart the server.
Configuring the Global Hot Spare Disk
  1. Restart the server using the iBMC remote virtual console. When the following page is displayed, press F11.

  2. Enter the password to access the configuration page.

    The initial password is Admin@9000

  3. Press arrow keys to select DeviceManager and press Enter.

  4. Press arrow keys to select AVAGO MegaRAID... and press Enter.

  5. Select <b>Main Menu</b> and press <b>Enter</b>.

  6. Press arrow keys to select Drive Management and press Enter.

  7. Press arrow keys to select the disk to be configured as the global hot spare disk and press Enter.

    Select a disk in the Unconfigured Good state as the global hot spare disk.

  8. Select Operation and press Enter.

  9. Press arrow keys to select Assign Global Hot Spare Drive and press Enter.

  10. Press arrow keys to select Go and press Enter.

  11. Press Enter and set Confirm to Enabled. Press arrow keys to select Yes and press Enter.

  12. Select OK and press Enter.

  13. After all configurations are complete, restart the server.

Changing the Server Boot Sequence

Before installing the operating system for a server, set the server to start from the CD-ROM.

Procedure
  1. Restart the server and wait until the "Press F11 go to Boot Manager (F3 on Remote Keyboard)" message is displayed.
  2. Press F11 or F3. The Enter Current Password dialog box is displayed.

  3. Enter the server BIOS password. The default password is Admin@9000.

  4. Press arrow keys to select Setup Utility and press Enter.

  5. Press arrow keys to select Boot > Boot Type and press Enter.

  6. Press arrow keys to select UEFI Boot and press Enter.

  7. Press arrow keys to select Boot Sequence and press Enter.

  8. Select Hard Disk Drive, and press F6 to change DVD-ROM Drive to the first one.

  9. Press F10 to save and exit.