eLog V200R007C10 Installation Guide

Describes the installation process of product software. Includes plans, environmental requirements, and procedures for installation, as well as commissioning procedures.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Stopping the Analyzer or Collector

Stopping the Analyzer or Collector

The analyzer or collector is started when the devices are delivered. Before you change the IP address of the operating system, you must stop the eLog analyzer or collector first.

Context

In centralized mode, you just need to stop the analyzer. In distributed mode, you need to stop both the analyzer and collector.

Procedure

  • Stop the analyzer.
    1. Log in to the server where the analyzer resides as the omm user.

      When you log in to the operating system as the omm user for the first time, you need to change the password. For details, see How to Change the Password of the omm User.

    2. Right-click the desktop and choose Open in Terminal from the shortcut menu to access the CLI.
    3. Run the cd software-installation-path/engineering/tools command to access the directory.

      The default directory is /opt/huawei/LogCenter/engineering/tools.

    4. Run the ./shutdown.sh command to stop the eLog.
      If the following output is displayed, the analyzer is shut down.
      System is shut down successfully.
  • Stop the collector.
    1. Log in to the server where the collector resides as the omm user.

      When you log in to the operating system as the omm user for the first time, you need to change the password. For details, see How to Change the Password of the omm User.

    2. Right-click the desktop and choose Open in Terminal from the shortcut menu to access the CLI.
    3. Run the cd software-installation-path/engineering/tools command to access the directory.

      The default directory is /opt/huawei/LogCenter/engineering/tools.

    4. Run the ./shutdown.sh command to shut down the eLog collector.
      If the following output is displayed,the collector is shut down.
      System is shut down successfully.