eLog V200R007C10 Installation Guide

Describes the installation process of product software. Includes plans, environmental requirements, and procedures for installation, as well as commissioning procedures.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Changing the Analyzer or Collector's IP Address

Changing the Analyzer or Collector's IP Address

This section describes how to change the IP address of a physical interface or the management IP address on the analyzer or collector.

Changing the Analyzer's IP Address

  1. Log in to the analyzer server as the root user.
  2. Right-click the desktop and choose Open in Terminal from the shortcut menu to access the CLI.
  3. Run the cd software-installation-path/engineering/tools command to access the directory.

    The default directory is /opt/huawei/LogCenter/engineering/tools.

  4. Run the ./config_network.sh command and choose to change the IP address of the analyzer's physical interface and to specify the service interface and web access interface as prompted.

    After the configuration is complete, the system automatically restarts the analyzer service.

    If the default gateway needs to be changed after the IP address is changed, see Setting the Default Gateway or Adding a Static Route.

    LogServer:~ # cd /opt/huawei/LogCenter/engineering/tools
    LogServer:/opt/huawei/LogCenter/engineering/tools # ./config_network.sh 
    Which operation do you want to execute?
    1) Change the IP address.  5) Modify the database.
    2) Delete the IP address.  6) Change the web port.
    3) Sweb et the gateway.	   7) Exit
    4) Configure DNS.
    #? 1                   
    |---------------------------- net interface status ----------------------------|
    Interface_Name   Interface_IP_Address   Bus_ID       Network_Cable    Service    Web_Access
     eth0             192.168.1.100          03:00.0           Y              N            N      
     eth1             192.168.2.100          0b:00.0           Y              Y            Y 
         
    Info: Do you want to change the interface IP address? [Y/N]: y     //Set an IP address for the physical interface.
    Info: Select an interface name.:
    1) eth0
    2) eth1
    #? 1
    Info: Enter an IP address in the X.X.X.X format. The new IP address will be configured for network interface eth0.
    Enter an IP address: 192.168.1.102
    Info: Enter a subnet mask for network interface eth0. The subnet mask is in the X.X.X.X or X format.
    Mask: 24
    Info: Succeeded in changing the IP address of network interface eth0 to 192.168.1.102/24.
    Info: Do you want to change the service IP address? [Y/N]:y   //Specify the service port for service communications with other components, such as the collector.
    Info: Select an interface name.:
    1) eth0
    2) eth1
    #? 1
    Info: Do you want to change the web access IP address? [Y/N]:y  //Specify the web access port used to provide web services and for user access.
    Info: Select an interface name.:
    1) eth0
    2) eth1
    #? 1
    Info: Modification succeeded, and the service will be restarted.
    All service stop success.
    service is starting,please wait...
    namingservice is starting,please wait... success.
    vap is starting,please wait..................... success.
    webservice is starting,please wait... success.
    All service startup success.

  5. In distributed deployment, if the analyzer's management IP address is changed, log in to the collector server and change the configured analyzer IP address.

    After the configuration is complete, the system automatically restarts the collector service.

    LogServer:~ # cd /opt/huawei/LogCenter/engineering/tools
    LogServer:/opt/huawei/LogCenter/engineering/tools # ./config_network.sh 
    Which operation do you want to execute?
    1) Change the IP address.  4) Configure DNS.
    2) Delete the IP address.  5) Modify the database.
    3) Set the gateway.?   6) Nothing
    #? 1 
    |---------------------------- net interface status ----------------------------|
    Interface_Name   Interface_IP_Address   Bus_ID       Network_Cable    Service    Web_Access
     eth0             192.168.1.100          03:00.0           Y              N            N      
     eth1             192.168.2.100          0b:00.0           Y              Y            N 
         
    Info: Do you want to change the interface IP address? [Y/N]: n     
    Info: Do you want to change the service IP address? [Y/N]:n   
    Info: Do you want to change the service IP address of the associated visualization server (namely, analyzer)? [Y/N]:y //Change the IP address of the associated analyzer.
    Info: Enter an IP address in the X.X.X.X format. The new IP address will be configured for network interface .
    Enter an IP address: 192.168.1.102
    Info: Receive Logs of All NICs ? [Y/N]:n  //Confirm whether to receive all NIC logs. Receiving all NIC logs greatly consumes resources and has security risks. Therefore, you are advised to enter n, so that the system receives only the logs related to the service interface selected in the previous step.
    Info: Modification succeeded, and the service will be restarted.
    All service stop success.
    service is starting,please wait...
    collector is starting,please wait.... success.
    webservice is starting,please wait..... success.
    All service startup success.

  6. On the web UI, choose System > SystemManagement > Host Management, click   to change the management IP address of the analyzer.

Changing the Collector's IP Address

  1. Log in to the collector server as the root user.
  2. Right-click the desktop and choose Open in Terminal from the shortcut menu to access the CLI.
  3. Run the cd software-installation-path/engineering/tools command to access the directory.

    The default directory is /opt/huawei/LogCenter/engineering/tools.

  4. Run the ./config_network.sh command and choose to change the IP address of the collector's physical interface and to specify the service interface as prompted.

    After the configuration is complete, the system automatically restarts the collector service.

    If the default gateway needs to be changed after the IP address is changed, see Setting the Default Gateway or Adding a Static Route.

    LogServer:~ # cd /opt/huawei/LogCenter/engineering/tools
    LogServer:/opt/huawei/LogCenter/engineering/tools # ./config_network.sh 
    Which operation do you want to execute?
    1) Change the IP address.  5) Modify the database.
    2) Delete the IP address.  6) Change the web port.
    3) Set the gateway.	   7) Exit
    4) Configure DNS.
    #? 1                   
    |---------------------------- net interface status ----------------------------|
    Interface_Name   Interface_IP_Address   Bus_ID       Network_Cable    Service    Web_Access
     eth0             192.168.1.100          03:00.0           Y              N            N      
     eth1             192.168.2.100          0b:00.0           Y              Y            N 
         
    Info: Do you want to change the interface IP address? [Y/N]: y     //Set an IP address for the physical interface.
    Info: Select an interface name.:
    1) eth0
    2) eth1
    #? 1
    Info: Enter an IP address in the X.X.X.X format. The new IP address will be configured for network interface eth0.
    Enter an IP address: 192.168.1.102
    Info: Enter a subnet mask for network interface eth0. The subnet mask is in the X.X.X.X or X format.
    Mask: 24
    Info: Succeeded in changing the IP address of network interface eth0 to 192.168.1.102/24.
    Info: Do you want to change the service IP address? [Y/N]:y   //Specify the service port for exchanging information with the analyzer and collecting logs reported by the log source.
    Info: Select an interface name.:
    1) eth0
    2) eth1
    #? 1
    Info: Do you want to change the service IP address of the associated visualization server (namely, analyzer)? [Y/N]:n//Whether to change the IP address of the analyzer associated with the collector.
    Info: Receive Logs of All NICs ? [Y/N]:n  //Confirm whether to receive all NIC logs. Receiving all NIC logs greatly consumes resources and has security risks. Therefore, you are advised to enter n, so that the system receives only the logs related to the service interface selected in the previous step.
    Info: Modification succeeded, and the service will be restarted.
    All service stop success.
    service is starting,please wait...
    collector is starting,please wait.... success.
    webservice is starting,please wait..... success.
    All service startup success.

  5. On the web UI, choose System > System Management > Host Management, click   to change the service IP address of the collector.

Verification

Log in to the web UI and choose System > System Management > HostManagement. You can see that both the visualization host and collector are in Online state.