No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

eLog V200R007C10 Installation Guide

Describes the installation process of product software. Includes plans, environmental requirements, and procedures for installation, as well as commissioning procedures.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Hardware and Software Configuration Requirements (Distributed Analyzer)

Hardware and Software Configuration Requirements (Distributed Analyzer)

Please prepare hardware and software and partition disks by strictly following the configuration requirement. Otherwise, problems, such as installation failures, login failures, or page anomalies, may occur. The recommended hardware is the server delivered along with the eLog. If you use other servers, the hardware configuration conditions must be met.

Software Planning for the Analyzer

For details on the analyzer software planning, see the following table.

Table 2-5 Software planning for the analyzer

Hardware Platform

Software Type

Version

x86(64bit)

Operating system

SUSE Linux 12 SP2(64bit)(Multi-language)

Database

MySQL5.7 (standard, delivered with the eLog software package)

Browsers

IE11, Firefox42 and above, Chrome41 and above browsers are recommended. Display resolution width 1280 is recommended.

NOTE:

During the installation of the eLog analyzer, the MySQL database is automatically installed.

Hardware Planning of the Analyzer

For details on the analyzer software planning, see the following table.

To use VMs, ensure that the specifications of the hardware server on which the VMs are installed are higher than the specifications listed in the table.

Table 2-6 Hardware planning of the analyzer

Item

Server Standard Configuration

VM Configuration (Exclusive Resources)

Server

Huawei Tecal RH2288H V5 (x86, 64-bit hardware platform)

For the server appearance, see RH2288H V5 Server Appearance.

  • Dimensions (D x W x H, mm): 748 x 447 x 86.1
  • Power consumption(w): maximum: 329; typical: 236; minimum: 135
  • Weight: 29 kg
  • Temperature:
    • Operating temperature: 5°C to 45°C (41°F to 113°F) (ASHRAE Class A3 and A4 compliant)
    • Storage temperature: –40°C to +65°C (–40°F to +149°F)
    • Temperature change rate: < 20°C/h (36°F/h)
    • Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)
  • Humidity:
    • Operating humidity: 8% RH to 90% RH (non-condensing)
    • Storage humidity: 5% RH to 95% RH (non-condensing)
    • Humidity change rate: < 20% RH/h
    • Long-term storage humidity: 30% RH to 69% RH
  • Altitude:
    • ≤ 3048 m (9999.88 ft). When the altitude is higher than 900 m (2952.72 ft), the operating temperature decreases by 1°C (1.8°F) as the altitude increases by 300 m (984.24 ft).
    • At an altitude of over 3000 m (9842.5 ft), only Titanium PSUs can be used.
    • HDDs are not supported at an altitude of over 3000 m (9842.5 ft).
  • Corrosive air pollutant:
    • Corrosion rate of the copper test piece: < 300 Å/month (in compliance with the ANSI/ISA-71.04-2013 gaseous corrosion level G1)
    • Corrosion rate of the silver test piece: < 200 Å/month
  • Particulate pollutant:
    • The ISO14664-1 Class 8 requirements are met.

      You are advised to ask a professional organization to monitor particulate pollutants in the equipment room.

    • There is no explosive, conductive, magnetic, or corrosive dust in the equipment room.

VMWare-ESXi 5.5/6.0

FusionSphere5.1 (V100R005C10)

FusionSphere6.0 (V100R006C00)

CPU

2 x ten-core, 2.2 GHz or higher (Xeon Silver 4114)

32-core vCPU, 2.6 GHz or higher

Memory

2 x 16 GB

32 GB

Disk space

System disk:

2 x 600 GB RAID1 SAS disk

NOTE:

The creation of RAID groups relies on the built-in RAID card of the server. Do not configure soft RAID groups repeatedly (such as configuring RAIDs in the operating system). Otherwise, the performance of the soft RAID groups will be greatly compromised.

Disk 1: 600 GB

Data disk:

6 x 2 TB SATA disk

Configure RAID6 and reserve one disk as the hot spare disk.

NOTE:

The creation of RAID groups relies on the built-in RAID card of the server. Do not configure soft RAID groups repeatedly (such as configuring RAIDs in the operating system). Otherwise, the performance of the soft RAID groups will be greatly compromised.

Disk 2: 6 TB

IO

When the following conditions are met, a single collector exclusively uses the IO:

Peak value: 300 MB/s or higher (at least 50 MB/s for writing the IO and 250 MB/s for reading the IO)

When the following conditions are met, a single collector exclusively uses the IO:

Peak value: 300 MB/s or higher (at least 50 MB/s for writing the IO and 250 MB/s for reading the IO)

NOTE:

The log collector is a disk I/O-intensive application. If the disk I/O performance is insufficient, the log processing performance is compromised.

Table 2-7 Recommended disk partitioning for the analyzer

Hardware Server Disk

VM Disk

Partition Type

Partition Path

Mount Point

File System

Recommended Storage Capacity

Description

Rear disks: 2 x 600G RAID1

Disk 1

UEFI boot partition

/dev/sda1

/boot/efi

FAT

150M

Required in UEFI boot mode

Swap partition

/dev/sda2

swap

Swap

32 GB

Partition that is used in system data transaction

Root partition

/dev/sda3

/

btrfs

100 GB

For installing the operating system

System process directory partition

/dev/sda4

/var

ext4

30G

Used to store dynamic data generated by daemon processes and other system service processes

Temporary file directory partition

/dev/sda5

/tmp

ext4

20G

Used to store temporary files generated by all users and certain applications

System log partition

/dev/sda6

/var/log

ext4

20G

Used to store system running logs

Audit log partition

/dev/sda7

/var/log/audit

ext4

10G

Used to audit background programs to calculate available space and perform operations based on the audit result

Software log partition

/dev/sda8

/opt/hwlog

ext4

50G

Used to store log files recorded during the running of the eLog service software

Local user data partition

/dev/sda9

/home

ext4

10G

Used to store local user data

Application software partition

/dev/sda10

/opt

ext4

282 GB

For installing application software

Front disks: 6x 2T Configure RAID6 and reserve one disk as the hot spare disk

Disk 2

Analyzer partition

/dev/sdb

/opt/huawei

XFS

-

For installing the operating system

Translation