Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the Installation

Verifying the Installation

This section describes how to verify the installation of the eLog analyzer software to ensure proper operating.

Procedure

  1. Use the root account to log in to the operating system.
  2. Right-click the desktop to open the terminal.
  3. Check whether the legoPlatInstalled.xml file exists.

    1. Run the cd /opt/huawei/LogCenter command to access the root installation directory of the eLog.
    2. Run the ls command to check whether the legoPlatInstalled.xml file exists.
    eLog:/opt/huawei/LogCenter/engineering/tools # cd /opt/huawei/LogCenter
    eLog:/opt/huawei/LogCenter # ls
    LegoRuntime bdbdata components engineering etc legoPlatInstalled.xml mysql

  4. Use the check_running.sh tool to view enabled services.

    1. Run the su omm command to switch to the omm user.
    2. Run the cd /opt/huawei/LogCenter/engineering/tools command to access the bin folder.
    3. Run the ./check_running.sh command to view running services.

      namingservice, vap, webservice and analyzer services are required.

      eLog:/opt/huawei/LogCenter/engineering/tools # su omm  
      omm@eLog:/opt/huawei/LogCenter/engineering/tools> ./check_running.sh  
      [INFO ][2018-02-19 11:27:29][analyzer][21]ST_RUNNING   
      [INFO ][2018-02-19 11:27:29][namingservice][21]ST_RUNNING  
      [INFO ][2018-02-19 11:27:19][vap][20]ST_RUNNING  
      [INFO ][2018-02-19 11:27:19][webservice][21]ST_RUNNING

      If any of the preceding services is not running, run the ./shutdown.sh command to shutdown the eLog and then run the ./startup.sh command to restart the eLog.