Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Security Hardening Rollback

Security Hardening Rollback

Security hardening rollback restores the status of ports, services, and remote control permissions to that before the security hardening.

Procedure

  1. Log in to the operating system as root.
  2. Right-click the desktop to open the terminal.
  3. Run the cd hardening-tool-directory command to access the directory where the hardening tool resides.
  4. Run the ./rollback.sh command to start rolling back.
  5. If the following information is displayed, security hardening rollback is complete.

    Rollback successfully, please reboot the system.

  6. Run the reboot command to validate the configuration.