Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring an Alarm Threshold

Configuring an Alarm Threshold

Scenarios

This section describes how to configure an alarm threshold for users to monitor indicators. When a monitoring item is enabled and the related indicator reaches the alarm threshold, an alarm is reported, which can be viewed by choosing O&M > Alarm > Alarm.

Procedure

  1. Log in to FusionInsight Manager.
  2. Click O&M.
  3. In Alarm, click Configure Alarm Threshold.

  4. Click an indicator, for example, Host CPU Usage, and click Create Rule.
  5. Set monitoring indicator rule parameters.

    Table 5-1 Description of monitoring indicator rule parameters

    Parameter

    Value

    Description

    Rule Name

    CPU_MAX (example value)

    Specifies the rule name. It cannot be modified after it takes effect.

    Severity

    • Critical
    • Major
    • Minor
    • Warning

    Specifies the alarm severity.

    • Critical
    • Major
    • Minor
    • Warning

    Threshold Type

    • Max value
    • Min value

    Specifies whether to use the maximum or minimum value of the indicator for setting the threshold. When this parameter is set to Maximum value, an alarm will be generated when the actual value of the indicator is greater than the threshold. When this parameter is set to Minimum value, an alarm will be generated when the actual value of the indicator is smaller than the threshold.

    Date

    • Workday
    • Weekend
    • Others

    Specifies the type of date when the rule takes effect.

    • Workday
    • Weekend
    • Others

    Configure Alarm Threshold

    • Start and End Time: From 00:00 to 24:00 (example value)
    • Threshold: 80 (example value)
    • Specifies the period in which the rule takes effect.
    • Specifies the threshold of the rule monitoring indicator. Enter a value from 0 to 100 with at most two digitsto the right of the decimal point.

  6. Click OK.

    • FusionInsight Manager checks whether the values of monitoring indicators meet the threshold requirements. If the number of times that the values do not meet the threshold requirements during consecutive checks exceeds the value of Trigger Count, an alarm will be sent. The value of Trigger Count can be customized.
    • Check Period(s) specifies the FusionInsight Managerto check monitoring indicators.

  7. In the line where the new rule is located, click Apply in the Operation column. A dialog box is displayed, indicating that the rule is successfully applied.