FusionInsight HD 6.5.0 Software Installation 02

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring a Northbound Interface (over Syslog)

Configuring a Northbound Interface (over Syslog)

Scenarios

Configure the northbound interface. In this way, alarms generated for FusionInsight Manager can be reported to your monitoring operation and maintenance system using Syslog.

The Syslog protocol does not support encryption. Therefore, data can be easily stolen during transmission. There are security risks.

Procedure

  1. Log in to FusionInsight Manager.
  2. Click System.
  3. In Interconnection, click Syslog.

    The default value of Syslog Service is off. If you set Syslog Service to , the Syslog service is started.

  4. On the displayed page, set Syslog parameters listed in Table 5-2:

    Table 5-2 Description of Syslog parameters

    Area

    Parameter

    Description

    Syslog Protocol

    Server IP

    Specifies the IP address of the interconnected server.

    Server Port

    Specifies the port number for interconnection.

    Protocol

    Specifies the protocol type, which can be:

    • TCP
    • UDP

    Severity

    Specifies the message severity, which can be:

    • Emergency
    • Alert
    • Critical
    • Error
    • Warning
    • Notice
    • Informational
    • Debug
      NOTE:

      Severity and Facility constitute the message priority.

      Priority = Facility x 8 +Severity

      For the values of Severity and Facility, see Table 5-3.

    Facility

    Specifies the module where the log is generated. For available values, see Table 5-3. The default value local use 0 (local0) is recommended.

    Identifier

    Specifies the product. The default value is FusionInsight Manager.

    Enter a maximum of 256 characters. Only letters, digits, underscores (_), spaces, periods (.), hyphens (-), and special characters including |${} are allowed.

    Report Message

    Report Message Format

    Specifies the message format of alarms. For details about the format requirements, see the help information on the WebUI.

    Enter a maximum of 1024 characters. Only letters, digits, underscores (_), spaces, periods (.), hyphens (-), and special characters including |${} are allowed.

    NOTE:

    For details about the message field in the report message format, see Table 5-4.

    Report Message Type

    Specifies the type of alarms to be reported.

    Report Message Level

    Specifies the severity of alarms to be reported.

    Uncleared Alarm Reporting

    Periodically Uncleared Alarm Reporting

    Specifies whether uncleared alarms are reported periodically. ON indicates that the function is enabled. OFF indicates that the function is disabled. The default value is OFF.

    Interval Time (Minute)

    Specifies the interval for periodical alarm report. When Periodically Uncleared Alarm Reporting is set to ON, the periodical alarm report function is enabled. The unit of the interval is minute and the default value is 15. The value range is 5 to 1440(one day).

    Heartbeat Settings

    Heartbeat Report

    Specifies whether periodical report of Syslog heartbeat messages is enabled. ON indicates that the function is enabled. OFF indicates that the function is disabled. The default value is OFF.

    Heartbeat Period (minutes)

    Specifies the interval for periodical heartbeat report. When Heartbeat Report is set to ON, the heartbeat report function is enabled. The unit of the interval is minute.and the default value is 15. The value range is 1 to 60.

    Heartbeat Packet

    Specifies the heartbeat report content. When Heartbeat Report is set to ON, the function is enabled. The identifier cannot be empty. The value must contain a maximum of 256 characters. It can contain only numbers, letters, underscores(_), vertical bars(|), colons(:), commas(,), periods(.), and spaces.

    NOTE:

    When the heartbeat packets are reported periodically, reporting packets may be interrupted in scenarios (active/standby OMS switchover) where some clusters are automatically restored from faults. Wait until the restoration is complete.

  5. Click OK to complete the settings.

Reference

Table 5-3 Numberical codes of Severity and Facility

Severity

Facility

Numberical Code

Emergency

kernel messages

0

Alert

user-level messages

1

Critical

mail system

2

Error

system daemons

3

Warning

security/authorization messages

4

Notice

messages generated internally by syslogd

5

Informational

line printer subsystem

6

Debug

network news subsystem

7

-

UUCP subsystem

8

-

clock daemon

9

-

security/authorization messages

10

-

FTP daemon

11

-

NTP subsystem 13 log audit

12

-

log audit

13

-

log alert

14

-

clock daemon

15

-

local use 0 to 7 (local0 to local7)

16~23

Table 5-4 Message field in the report message format

Message Field

Decription

dn

Cluster name

id

Alarm ID

name

Alarm name

serialNo

Alarm serial number

NOTE:

A fault alarm and its recovery alarm must have the same alarm ID.

category

Alarm type. Possible values are:

  • 0:Fault alarm
  • 1:Recovery alarm
  • 2:Event

occurTime

Alarm generation time

clearTime

Alarm clearance time

isAutoClear

Whether the alarm is automatically cleared. Possible values are:

  • 1:Yes
  • 0:No

locationInfo

Alarm location information

clearType

Alarm clearance type. Possible values are:

  • -1:Not cleared
  • 0:Automatically cleared
  • 2:Manually cleared

level

Alarm severity. Possible values are:

  • 1:Critical
  • 2:Major
  • 3:Minor
  • 4:Info

cause

Alarm cause

additionalInfo

Additional information

Download
Updated: 2019-05-17