This document describes the configurations of Device Management, including device status query, hardware management, Information Center Configuration, NTP, Synchronous Ethernet Configuration, Fault Management Configuration, Energy-Saving Management Configuration, Performance Management Configuration, Maintenance Assistant Configuration, and OPS Configuration.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Enabling Access Control of 1588v2 Clock Sources

(Optional) Enabling Access Control of 1588v2 Clock Sources

Context

If a 1588v2 network is large, a large number of devices may participate in dynamic clock source selection. Malicious clock attacks or incorrect configurations will cause clock flapping over the 1588v2 network. You can enable access control of clock sources so that a 1588v2 switch selects a clock source within a specified range.

Perform the following steps on each 1588v2 device.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run ptp acl enable

    Access control of clock sources is enabled.

    By default, access control of clock sources is disabled.

  3. Run ptp acl-permit-clockid clockid-value

    A clock ID is set for a 1588v2 device allowed to participate in local BMC calculation.

    By default, after access control of clock sources is enabled, no clock source participates in clock source selection if no clock ID range is specified for clock sources allowed to participate in clock source selection.

  4. Run commit

    The configuration is committed.