Configuration Guide - Device Management

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Device Management, including device status query, hardware management, Information Center Configuration, NTP, Synchronous Ethernet Configuration, Fault Management Configuration, Energy-Saving Management Configuration, Performance Management Configuration, Maintenance Assistant Configuration, and OPS Configuration.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for Energy-Saving Management

Licensing Requirements and Limitations for Energy-Saving Management

Involved Network Elements

No other NEs are required.

Licensing Requirements

Energy-saving management is a basic switch feature and is not under license control.

Version Requirements

Table 8-1 Minimum version supporting energy-saving management

Product

Minimum Version Required

CE12804/CE12808/CE12812

V100R001C00

CE12816

V100R003C00

CE12804S/CE12808S

V100R005C00

CE12804E/CE12808E/CE12816E

V200R002C50

Feature Limitations

  • When ALS is enabled and the manual restart mode is configured on physical stack member interfaces, the local interface becomes Up and the peer interface becomes Down if the shutdown and then undo shutdown commands are executed on the peer interface. The two interfaces become Up after the als restart command is executed on the local interface.
  • Only electrical interfaces except management ports support the EEE function. A GE or 10GE optical interface does not support the EEE function even if an SFP-GE electrical module is inserted.
  • The EEE function takes effect only when it is configured on both ends of a link.
  • Only GE electrical ports except management ports support the port dormancy function.