Configuration Guide - Device Management

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Device Management, including device status query, hardware management, Information Center Configuration, NTP, Synchronous Ethernet Configuration, Fault Management Configuration, Energy-Saving Management Configuration, Performance Management Configuration, Maintenance Assistant Configuration, and OPS Configuration.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Alarm Correlation Suppression

Configuring Alarm Correlation Suppression

Context

Before configuring alarm correlation suppression, enable alarm correlation analysis to analyze alarm types including root-cause and non-root-cause. For a non-root-cause alarm, the system marks the sequence number of its root-cause alarm on the non-root-cause alarm. After alarm correlation suppression is configured, the system filters out non-root-cause alarms and reports only root-cause alarms to the NMS.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run alarm

    The alarm view is displayed.

  3. Run correlation-analyze enable

    Alarm correlation analysis is enabled.

    By default, alarm correlation analysis is disabled.

  4. Run the following commands to configure NMS-based alarm correlation suppression.

    • Run alarm correlation-suppress enable target-host ip-address securityname { securityname | cipher securityname } [ vpn-instance vpn-instance-name ]

      Alarm correlation suppression based on the NMS IPv4 address is enabled.

    • Run alarm correlation-suppress enable target-host ipv6 ipv6-address securityname { securityname | cipher securityname } [ vpn-instance vpn-instance-name ]

      Alarm correlation suppression based on the NMS IPv6 address is enabled.

    By default, NMS-based alarm correlation suppression is enabled.

  5. Run commit

    The configuration is committed.