Configuration Guide - Device Management

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Device Management, including device status query, hardware management, Information Center Configuration, NTP, Synchronous Ethernet Configuration, Fault Management Configuration, Energy-Saving Management Configuration, Performance Management Configuration, Maintenance Assistant Configuration, and OPS Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Serdes Rate Mode Between LPUs and SFUs

Configuring the Serdes Rate Mode Between LPUs and SFUs

Context

The Serdes rate between LPUs and SFUs has two modes: enhanced mode and non-enhanced mode, which provide different Serdes rates.
Table 2-6 Serdes rate between LPUs and SFUs

SFU Type

LPU Type

Serdes Rate Mode ( Non-enhanced Mode )

Serdes Rate Mode ( Enhanced Mode )

SUFA, SUFB, and SUFC

EA, EC, ED, EF, EG, and BA LPUs

11.25 Gbit/s

10.3125 Gbit/s

FG, FG1, FD1, SD, FD and FDA LPUs

-

-

SFUF and SFUG

EA, EC, ED, EF, EG, and BA LPUs

11.25 Gbit/s

10.3125 Gbit/s

FG, FG1, FD1, SD, FD and FDA LPUs

25 Gbit/s

25.78 Gbit/s

NOTE:

When a switch has SFUAs, SFUBs, or SFUCs installed, the switch cannot have FG, FG1, FD1, SD, FD and FDA LPUs installed. When a switch has FG, FG1, FD1, SD, FD or FDA LPUs installed, the switch cannot have SFUAs, SFUBs, or SFUCs installed.

When CE-L16CQ-FD/FG/FD1/FG1/SD and FD (except CE-L16CQ-FD)/FDA series LPUs are used on the same switch, if the Serdes rate mode is set to enhanced mode using the set serdes capability enhanced command, some Serdes links of CE-L16CQ-FD/FG/FD1/FG1/SD will be shut down, affecting the card forwarding performance.

CE12800E does not support this function.

Procedure

  1. Run the system-view command to enter the system view.
  2. Run the set serdes capability enhanced [ chassis chassis-id ] command to set the Serdes rate mode between LPUs and SFUs.

    By default, the Serdes rate mode between LPUs and SFUs is non-enhanced mode.

    NOTE:

    The set serdes capability enhanced command configuration takes effect after the switch is restarted.

  3. Run commit

    The configuration is committed.

Translation