Configuration Guide - Device Management

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Device Management, including device status query, hardware management, Information Center Configuration, NTP, Synchronous Ethernet Configuration, Fault Management Configuration, Energy-Saving Management Configuration, Performance Management Configuration, Maintenance Assistant Configuration, and OPS Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Extended Layer 3 Forwarding Resource Mode for a Card (CE12800)

Configuring the Extended Layer 3 Forwarding Resource Mode for a Card (CE12800)

Context

By default, 1M IPv4 FIB entries are available as extended Layer 3 forwarding resources of cards, and error checking and correction (ECC) will be performed through hardware. To adjust the FIB table specifications, run the assign forward command to set the extended Layer 3 forwarding resource mode to no-ecc. Subsequently, 2M IPv4 FIB entries are available. If you set the extended Layer 3 forwarding resource mode to ipv4-ipv6, 256K IPv4 FIB entries and 256K IPv6 FIB entries are available. If you set the extended Layer 3 forwarding resource mode to no-ecc or ipv4-ipv6, ECC will be performed through software.

NOTE:
  • Only CE-L12CF-EG and CE-L36LQ-EG cards support this configuration.

  • Only CE-L36LQ-EG cards support the ipv4-ipv6 mode.

  • If the extended Layer 3 forwarding resource mode of a card has been set to no-ecc, ports on the card cannot be assigned to two or more VSs in group mode. If ports on a card have been assigned to two or more VSs in group mode, the extended Layer 3 forwarding resource mode of this card cannot be set to no-ecc.

Procedure

  1. (Optional) Run the display forward no-ecc [ slot slot-id ] command to check the current extended Layer 3 forwarding resource mode of a specified card.
  2. Run the system-view command to enter the system view.
  3. Run the assign forward { no-ecc | ecc ipv4-ipv6 } slot slot-id command to configure the extended Layer 3 forwarding resource mode of a specified card.

    By default, no extended Layer 3 forwarding resource mode is configured for cards.

    NOTE:

    This command takes effect after cards are restarted.

  4. Run the commit command to commit the configuration.
  5. Run the quit command to exit from the system view.
  6. Run the reset slot slot-id command to restart the card to make the configuration take effect.