Configuration Guide - Device Management

CloudEngine 12800 and 12800E V200R005C10

This document describes the configurations of Device Management, including device status query, hardware management, Information Center Configuration, NTP, Synchronous Ethernet Configuration, Fault Management Configuration, Energy-Saving Management Configuration, Performance Management Configuration, Maintenance Assistant Configuration, and OPS Configuration.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for 1588v2

Licensing Requirements and Limitations for 1588v2

Involved Network Elements

External clock source

Licensing Requirements

For the CE12800E equipped with ED-E/EG-E/EGA-E series cards, in versions earlier than V200R005C10, 1588v2 is a basic switch feature and is not under license control. In V200R005C10 and later versions, 1588v2 is controlled by a license and is disabled by default. To use 1588v2 on the CE12800E equipped with ED-E/EG-E/EGA-E series cards, apply for and purchase the license from the equipment supplier.

For the CE12800E equipped with FD-X series cards,1588v2 is controlled by a license and is disabled by default. To use the 1588v2 function, apply for and purchase the license from the equipment supplier.

Version Requirements

Table 6-1 Products and minimum version supporting 1588v2

Product

Minimum Version Required

CE12800E configured with ED-E/EG-E/EGA-E/FD-X series cards

V200R005C00

Feature Limitations

  • To achieve time synchronization, all devices on a link must support 1588v2. Currently, a maximum of 20 devices are allowed on a link for time synchronization.
  • Devices support external time source backup if BITS1 ports on the active and standby MPUs are connected to the same time source.
  • Ports that do not have 1588v2 enabled transparently forward received MAC-encapsulated 1588v2 packets.
  • For the CE12800E, the ports obtained after port splitting do not support 1588v2.
  • When a CE12800E equipped with ED-E/EG-E/EGA-E series cards is upgraded from V200R005C00 to V200R005C10 or a later version, the existing 1588v2 configuration is not affected, but the 1588v2 configuration cannot be added or modified. You are advised to apply for and load a 1588v2 license after the upgrade.