No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EFM_1.3.6.1.4.1.2011.5.25.136.1.6.4 threshold

EFM_1.3.6.1.4.1.2011.5.25.136.1.6.4 threshold

Description

Threshold event occured. (IfIndex=[INTEGER], EventLogIndex=[GAUGE], EventLogTimestamp=[TIMETICK], EventLogOui=[OPAQUE], EventLogType=[GAUGE], EventLogLocation=[INTEGER], EventLogWindowHi=[GAUGE], EventLogWindowLo=[GAUGE], EventLogThresholdHi=[GAUGE], EventLogThresholdLo=[GAUGE], EventLogValue=[COUNTER64], EventLogRunningTotal=[COUNTER64], EventLogEventTotal=[GAUGE], IfName=[OCTET])

The number of errored frames, errored codes, or errored frame seconds exceeded the set threshold within the specified period.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Error

Mnemonic Code

threshold

Trap OID

1.3.6.1.4.1.2011.5.25.136.1.6.4

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter

Description

IfIndex Interface index.
EventLogIndex Index of ta printed log.
EventLogTimestamp Timestamp that records when an event occurred.
EventLogOui Name of an outbound interface of an event.
EventLogType Type of an event.
EventLogLocation Where the event occurs, on the local or remote end (1 indicates local end, 2 indicates peer end).
EventLogWindowHi High-order value of a monitoring interval.
EventLogWindowLo Low-order value of a monitoring interval.
EventLogThresholdHi High-order value of the threshold of a monitoring interval.
EventLogThresholdLo Low-order value of the threshold of a monitoring interval.
EventLogValue Number of times that a threshold-crossing event occurs.
EventLogRunningTotal Number of event occurrences.
EventLogEventTotal Number of event notifications.
IfName Interface name.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.2

hwDot3ahEfmEventLogTimestamp

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.3

hwDot3ahEfmEventLogOui

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.4

hwDot3ahEfmEventLogType

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.5

hwDot3ahEfmEventLogLocation

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.6

hwDot3ahEfmEventLogWindowHi

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.7

hwDot3ahEfmEventLogWindowLo

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.8

hwDot3ahEfmEventLogThresholdHi

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.9

hwDot3ahEfmEventLogThresholdLo

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.10

hwDot3ahEfmEventLogValue

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.11

hwDot3ahEfmEventLogRunningTotal

ifIndex

hwDot3ahEfmEventLogIndex

1.3.6.1.4.1.2011.5.25.136.1.2.2.7.1.12

hwDot3ahEfmEventLogEventTotal

ifIndex

hwDot3ahEfmEventLogIndex

Impact on the System

Services cannot be forwarded.

Possible Causes

Cause 1:

The user configured the efm error-code threshold 0, efm error-frame threshold 0 or efm error-frame-second threshold 0 command on the interface.

Cause 2:

The physical link became faulty, causing the error frame or error code.

Procedure

  1. Check the value of the EventLogType field in the trap:

    • 1: an errored code alarm. Then go to 2.

    • 2: an errored frame alarm. Then go to 3.

    • 4: an errored frame second alarm. Then go to 4.

  2. Run the display this command in the interface view. Check whether the efm error-code threshold 0 command is displayed in the command output.

    • If this command is displayed, go to 6.

    • If this command is not displayed, go to 5.

  3. Run the display this command in the interface view. Check whether the efm error-frame threshold 0 command is displayed in the command output.

    • If this command is displayed, go to 7.

    • If this command is not displayed, go to 5.

  4. Run the display this command in the interface view. Check whether the efm error-frame-second threshold 0 command is displayed in the command output.

    • If this command is displayed, go to 8.

    • If this command is not displayed, go to 5.

  5. Check whether a physical link fails.

    • If the physical link is working properly, go to 9.

    • If the physical link fails, go to 10.

  6. Run the efm error-code threshold threshold command in the interface view to set the EFM errored code detection threshold for the interface. Check whether a new event is continuously reported.

    • If a new event is continuously reported, go to 10.

    • If no new event is continuously reported, go to 11.

  7. Run the efm error-frame threshold threshold command in the interface view to set the EFM errored frame detection threshold for the interface. Check whether a new event is continuously reported.

    • If a new event is continuously reported, go to 10.

    • If no new event is continuously reported, go to 11.

  8. Run the efm error-frame-second threshold threshold command in the interface view to set the EFM errored frame seconds detection threshold for the interface. Check whether a new event is continuously reported.

    • If a new event is continuously reported, go to 10.

    • If no new event is continuously reported, go to 11.

  9. Rectify the physical link fault and check whether a new event is continuously reported.

    • If a new event is continuously reported, go to 10.

    • If no new event is continuously reported, go to 11.

  10. Collect the alarm, log, and configuration information, and then contact technical support personnel.
  11. End.
Translation
Download
Updated: 2019-04-02

Document ID: EDOC1100074754

Views: 25763

Downloads: 31

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next