Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SNMP_1.3.6.1.6.3.1.1.5.1 coldStart

SNMP_1.3.6.1.6.3.1.1.5.1 coldStart

Description

OID [oidname] coldStart.

The device was cold started.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

coldStart

Trap OID

1.3.6.1.6.3.1.1.5.1

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

oidname

OID name of an object

VB

VB OID

VB Name

VB Index

N/A

N/A

N/A

Impact on the System

Services are not affected.

Possible Causes

The system restarted because of power-off.

Procedure

  • The system restarted because of power-off.
    1. Check whether the power cables are installed properly.

      • If the power cables are installed properly, go to Step 2.
      • If the power cables are installed improperly, install the power cables properly.

    2. Check whether the device is restarted by the maintenance personnel.

      • If the device is restarted by the maintenance personnel, no action is required.
      • If the device is not restarted by the maintenance personnel, go to Step 3.

    3. Check whether the power supply system is working stably.

      • If the power supply system is working stably, go to Step 4.
      • If the power supply system is not working stably, contact engineers of the power supply department.

    4. Collect the alarm information, log information, and configurations, and then contact technical support personnel.