Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.13 hwStackLogicStackPortLinkErrResume

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.13 hwStackLogicStackPortLinkErrResume

Description

The interface Stack-Port was linked invalidly resume. (hwStackLocalIfName=[hwStackLocalIfName], hwStackPeerIfName=[hwStackPeerIfName], Reason=[Reason])

The fault in physical member interface connection was rectified.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwStackLogicStackPortLinkErrResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.13

Alarm ID

0x09a20010

Alarm Type

environmentalAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.9 hwStackLogicStackPortLinkErr

Parameters

Name Meaning

hwStackLocalIfName

Indicates the name of the local stack port.

hwStackPeerIfName

Indicates the name of the peer stack port.

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.1

hwStackLocalIfName

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.2

hwStackPeerIfName

N/A

Impact on the System

The stack link fault is rectified, and the stack can be created successfully.

Possible Causes

Physical member interfaces of the stack interface were connected correctly.

Procedure

  1. This trap message is informational only, and no action is required.