Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.19 hwStackFabricPortLinkErrResume

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.19 hwStackFabricPortLinkErrResume

Description

The interface Fabric-Port was linked invalidly resume. (hwStackFabricPort=[hwStackFabricPort], hwStackFabricMemberPort=[hwStackFabricMemberPort], hwStackPeerPort=[hwStackPeerPort], Reason=[Reason])

The fault that the Fabric ports in the SVF are incorrectly connected is rectified.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwStackFabricPortLinkErrResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.19

Alarm ID

0x09a22016

Alarm Type

environmentalAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.18 hwStackFabricPortLinkErr

Parameters

Parameter Meaning

hwStackFabricPort

Indicates the Fabric port.

hwStackFabricMemberPort

Indicates the member port of the Fabric port.

hwStackPeerPort

Indicates the peer port.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.9

hwStackFabricMemberPort

N/A

Impact on the System

The SVF links are recovered, and the SVF can be established.

Possible Causes

The Fabric ports are correctly connected.

Procedure

  1. This log message is informational only, and no action is required.