No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ARP_1.3.6.1.4.1.2011.5.25.123.2.21 hwARPBDHostConflictAlarm

ARP_1.3.6.1.4.1.2011.5.25.123.2.21 hwARPBDHostConflictAlarm

Description

Host IP address conflicted. (LocalIPAddress=[LocalIP], LocalBDID=[LocalBDId], LocalMAC=[LocalMAC], RemoteIPAddress=[ConflictIP], RemoteBDID=[RemoteBDId], RemoteMAC=[RemoteMAC], LocalInterface=[LocalInterface], RemoteInterface=[RemoteInterface], TunnelPeer=[TunnelPeer])

A host IP address conflict occurred.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwARPBDHostConflictAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.123.2.21

Alarm ID

0x00F10287

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

ARP_1.3.6.1.4.1.2011.5.25.123.2.22 hwARPBDHostConflictResume

Parameters

Parameter Description

LocalIPAddress

Local IP address

LocalBDID

Local BD ID

LocalMAC

Local MAC address

RemoteIPAddress

Remote IP address

RemoteBDID

Remote BD ID

RemoteMAC

Remote MAC address

LocalInterface

Local interface

RemoteInterface

Remote interface

TunnelPeer

Peer IP address of the tunnel

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.123.1.38.1

hwARPLocalIPAddr

None

1.3.6.1.4.1.2011.5.25.123.1.38.2

hwARPLocalBDId

None

1.3.6.1.4.1.2011.5.25.123.1.38.3

hwARPLocalMAC

None

1.3.6.1.4.1.2011.5.25.123.1.38.4

hwARPRemoteIPAddr

None

1.3.6.1.4.1.2011.5.25.123.1.38.5

hwARPRemoteBDId

None

1.3.6.1.4.1.2011.5.25.123.1.38.6

hwARPRemoteMAC

None

1.3.6.1.4.1.2011.5.25.123.1.38.7

hwARPLocalInterface

None

1.3.6.1.4.1.2011.5.25.123.1.38.8

hwARPRemoteInterface

None

1.3.6.1.4.1.2011.5.25.123.1.38.9

hwARPTunnelPeer

None

Impact on the System

A board-level or device-level fault may occur.

Possible Causes

Hosts with the same IP address exist on a BD.

Procedure

  1. Confirm the conflicting host according to the alarm information.

    • If the conflicting host can be confirmed, go to Step 2.
    • If the conflicting host cannot be confirmed, go to Step 3.

  2. Change the IP address of the conflicting host and check whether the alarm persists.

    • If the alarm persists, go to Step 3.
    • If the alarm is cleared, go to Step 4.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.
Translation