Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ARP_1.3.6.1.4.1.2011.5.25.123.2.20 hwEthernetARPLimitExceedResume

ARP_1.3.6.1.4.1.2011.5.25.123.2.20 hwEthernetARPLimitExceedResume

Description

The number of ARP entries learned on the interface fell below the threshold. (Interface name=[InterfaceName], Maximum number of ARP entries=[LimitNumber], Number of learned ARP entries =[LearnedNumber], Reason for clearing the alarm=[RecoverReason])

The number of dynamic ARP entries learned on the interface fell below the alarm clearance threshold. The alarm clearance threshold is 5% less than the alarm threshold. For example, if the alarm threshold is 80%, the alarm clearance threshold is 75%.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

INTERFACE_ARP_EXCEED

Trap OID

1.3.6.1.4.1.2011.5.25.123.2.20

Alarm ID

0x00F101f1

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Clear

Match trap

ARP_1.3.6.1.4.1.2011.5.25.123.2.19 hwEthernetARPLimitExceed

Parameters

Parameter Description

Interface name

Interface name

Maximum number of ARP entries

Maximum number of dynamic ARP entries that an interface can learn

Number of learned ARP entries

Number of dynamic ARP entries that an interface has learned

Reason for clearing the alarm

Reasons for clearing the alarm:

  • The alarm function is disabled.
  • The maximum number of dynamic ARP entries that an interface can learn is increased.
  • The number of learned dynamic ARP entries is reduced to the specified range.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.123.1.37.1.1

hwEthernetARPLimitExceedInterface

N/A

1.3.6.1.4.1.2011.5.25.123.1.37.1.2

hwEthernetARPLimitExceedLimitNumber

N/A

1.3.6.1.4.1.2011.5.25.123.1.37.1.3

hwEthernetARPLimitExceedLearntNumber

N/A

Impact on the System

None

Possible Causes

The number of dynamic ARP entries learned on the interface fell below the specified alarm clearance threshold.

Procedure

  1. This trap message is informational only, and no action is required.
Translation