Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm

DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm

Description

The board temperature exceeded the upper alarm threshold.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The board or card temperature was too high.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwBrdTempAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.10.13

Alarm ID

0x0813000d

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.14 hwBrdTempAlarmResume

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityThresholdType

Indicates the threshold type of the entity.

EntityThresholdCritical

Indicates the temperature threshold of the entity.

EntityThresholdCurrent

Indicates the current temperature.

EntityTrapFaultID

Indicates the error code.
  • 143617
  • 143616

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.1 hwEntityThresholdType entPhysicalIndex
1.3.6.1.4.1.2011.5.25.219.1.5.1.5 hwEntityThresholdWarning entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.3

hwEntityThresholdCurrent

entPhysicalIndex
1.3.6.1.4.1.2011.5.25.219.1.3 hwEntityTrapFaultID

N/A

Impact on the System

Services are not affected in a short time, but the board or card temperature needs to be reduced.

Possible Causes

Cause 1 (EntityTrapFaultID=[143617]): The board temperature was too high.

Cause 2 (EntityTrapFaultID=[143616]): The card temperature was too high.

Procedure

  1. Check whether the air filter of the fan is blocked.

    • If so, clean the air filter.

    • If not, go to step 2.

  2. Check whether the ambient temperature is too high.

    • If so, reduce the ambient temperature.

    • If not, go to step 3.

  3. Check whether the fan is faulty.

    • If so, rectify the fan fault.

    • If not, go to step 4.

  4. Check whether a filler panel is installed in the slot that has no board or subcard installed.

    • If so, go to step 5.

    • If not, install a filler panel in the slot.

  5. Collect traps, logs, and configurations, and contact technical support personnel.