Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PIM_1.3.6.1.4.1.2011.5.25.149.4.0.34 hwPimRpfFlapping

PIM_1.3.6.1.4.1.2011.5.25.149.4.0.34 hwPimRpfFlapping

Description

The RPF route is flapping. (AddressFamily=[AddressFamily], SrcAddr=[SrcAddr], InstanceName=[InstanceName])

The RPF route flapped.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwPimRpfRtFlapping

Trap OID

1.3.6.1.4.1.2011.5.25.149.4.0.34

Alarm ID

0x00f102c5

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

PIM_1.3.6.1.4.1.2011.5.25.149.4.0.35 hwPimRpfRtFlappingClear

Parameters

Parameter Description

AddressFamily

Address family

SrcAddr

Multicast source address

InstanceName

Instance name

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.149.4.1.62

hwPimNotificationAddressType

N/A

1.3.6.1.4.1.2011.5.25.149.4.1.69

hwPimNotificationSrcAddr

N/A

1.3.6.1.4.1.2011.5.25.149.4.1.60

hwPimInstanceName

N/A

Impact on the System

After the RPF route flapped, packet loss may occur during data forwarding.

Possible Causes

The RPF route was unstable.

Procedure

  1. Check whether AddressFamily is IPv4. If AddressFamily is IPv4, the alarm is triggered in the IPv4 address family. Perform the following operations:
    1. Run the display ip routing-tablecommand to check whether the unicast route to the neighbor is normal.

      • If the unicast route to the neighbor is abnormal, go to Step b.

      • If the unicast route to the neighbor is abnormal, rectify the fault and go to Step c.

    2. Collect alarm information and configuration information, and then contact technical support personnel.
    3. End.
  2. Check whether AddressFamily is IPv6. If AddressFamily is IPv6, the alarm is triggered in the IPv6 address family. Perform the following operations:
    1. Run the display ipv6 routing-table command to check whether the unicast route to the neighbor is normal.

      • If the unicast route to the neighbor is abnormal, go to Step b.

      • If the unicast route to the neighbor is abnormal, rectify the fault and go to Step c.

    2. Collect alarm information and configuration information, and then contact technical support personnel.