Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.18 hwStackFabricPortLinkErr

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.18 hwStackFabricPortLinkErr

Description

The interface Fabric-Port was linked invalidly. (hwStackFabricPort=[hwStackFabricPort], hwStackFabricMemberPort=[hwStackFabricMemberPort], hwStackPeerPort=[hwStackPeerPort], Reason=[Reason])

The Fabric ports in the SVF are incorrectly connected.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwStackFabricPortLinkErr

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.18

Alarm ID

0x09a22016

Alarm Type

environmentalAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.19 hwStackFabricPortLinkErrResume

Parameters

Parameter Meaning

hwStackFabricPort

Indicates the Fabric port.

hwStackFabricMemberPort

Indicates the member port of the Fabric port.

hwStackPeerPort

Indicates the peer port.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.9

hwStackFabricMemberPort

N/A

Impact on the System

The SVF links are unavailable, and the SVF may fail to be established.

Possible Causes

Cause 1: One Fabric port is connected to more than one leaf switch.

Cause 2: The Fabric ports on the spine switch are connected to each other.

Cause 3: One leaf switch is connected to more than one Fabric port.

Cause 4: The member port of a Fabric port is connected to an isolated port.

Cause 5: The member port of a Fabric port is connected to the member port of a stack port.

Cause 6: A leaf switch is connected to multiple stack systems.

Procedure

  1. Run the display interface brief command to view the member ports of the Fabric port and check whether the member ports are connected.

    • If so, disconnect the ports.
    • If not, go to step 2.

  2. Check whether one Fabric port is connected to only one leaf switch and whether the leaf switch is only connected to this Fabric port.

    • If so, go to step 3.
    • If not, modify the connections based on rules.

  3. Collect traps, logs, and configurations, and contact technical support personnel.
Translation
Download
Updated: 2019-04-02

Document ID: EDOC1100074754

Views: 25339

Downloads: 31

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next