No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ISIS_1.3.6.1.3.37.2.0.6 isisMaxAreaAddressesMismatch

ISIS_1.3.6.1.3.37.2.0.6 isisMaxAreaAddressesMismatch

Description

The MaxAreaAddress field of received PDU is different from local configuration. (isisSysInstance=[isisSysInstance], isisSysLevelIndex=[isisSysLevelIndex], isisPduMaxAreaAddress=[isisPduMaxAreaAddress], isisCircIndex=[isisCircIndex], isisCircIfIndex=[isisCircIfIndex], isisPduFragment=[isisPduFragment], ifIndex=[ifIndex], IfName=[IfName])

The maximum number of area addresses in a received PDU was different from the locally supported one.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Critical

Mnemonic Code

isisMaxAreaAddressesMismatch

Trap OID

1.3.6.1.3.37.2.0.6

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

isisSysInstance

Indicates the ID of the IS-IS process.

isisSysLevelIndex

Indicates the IS-IS level:
  • 1: Level-1

  • 2: Level-2

isisPduMaxAreaAddress

Indicates the maximum number of area addresses.

isisCircIndex

Indicates the index of the interface.

isisCircIfIndex

Indicates the index of the interface.

isisPduFragment

Indicates the fragment of 64-byte PDU header.

ifIndex

Indicates the IF index of the interface.

IfName

Indicates the name of the interface.

VB

VB OID

VB Name

VB Index

1.3.6.1.3.37.1.1.1.1.1

isisSysInstance

isisSysInstance

1.3.6.1.3.37.1.2.1.1.1

isisSysLevelIndex

isisSysInstance

isisSysLevelIndex

1.3.6.1.3.37.1.10.1.1.4

isisPduMaxAreaAddress

isisSysInstance

1.3.6.1.3.37.1.3.1.1.2

isisCircIfIndex

isisSysInstance

isisCircIndex

1.3.6.1.3.37.1.10.1.1.2

isisPduFragment

isisSysInstance

Impact on the System

1. If the trap is triggered by a hardware fault of the device, route flapping may occur and the CPU usage will increase.

2. If the trap is triggered because of the intercommunication failure between s, neighbors cannot be established, and routes cannot be learnt from each other.

Possible Causes

1. The maximum number of area addresses supported by the local mismatch the number of area addresses supported by other s.

2. The maximum area address field was modified.

Procedure

  1. Based on the IS-IS packet format defined in ISO10589, search for the pdu-fragment field (in hexadecimal) in the trap and fetch the system ID of the source . Then, find the value of the pdu-max-area field in the trap and check whether the number of maximum area addresses is neither 0 nor 3.

    • If so, go to Step 2.

    • If not, go to Step 3.

    Table 32-2 Methods of searching for system IDs and types of IS-IS packets

    Searching for the Packet Type

    Searching for the System ID

    Hello: the 5th byte in the pdu-fragment field being 0f, 10, or 11

    The system ID is continuous 6 bytes after the 10th byte in the pdu-fragment field

    LSP: the 5th byte in the pdu-fragment field being 12 or 14

    The system ID is continuous 6 bytes after the 13th byte in the pdu-fragment field

    SNP: the 5th byte in the pdu-fragment field being 18, 19, 1A, or 1B

    The system ID is continuous 6 bytes after the 11th byte in the pdu-fragment field

  2. Modify the maximum number of area addresses of the source to 3. Then, check whether the trap is cleared.

    • If so, go to Step 6.

    • If not, go to Step 3.

  3. View the logs or ping the device to check whether the device has a fault and hence the packet is tampered.

    • If so, go to Step 4.

    • If not, go to Step 5.

  4. Collect the trap information, log information, and configuration of the , and contact technical support personnel technical personnel.