Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CONFIGURATION_1.3.6.1.4.1.2011.6.10.2.1 hwcfgmaneventlog

CONFIGURATION_1.3.6.1.4.1.2011.6.10.2.1 hwcfgmaneventlog

Description

Configuration file was changed. (LogIndex=[integer], SrcCmd=[integer], SrcData=[integer], DestData=[integer], TerUser="[DisplayString]", SrcAddr=[InetAddress], ConfigChangeId=[Unsigned32], LogTime=[TimeTicks], CfgBaselineTime="[DisplayString]")

The configuration file changed.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Informational

Mnemonic Code

hwCfgManEventlog

Trap OID

1.3.6.1.4.1.2011.6.10.2.1

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

LogIndex

Indicates the index of an event.

SrcCmd

Indicates the source of a command.

SrcData

Indicates the source of a configuration.

DestData

Indicates the destination of a configuration.

TerUser

Indicates the terminal users during the configuration change.

SrcAddr

Indicates the source address of a command.

ConfigChangeId

Indicates the ID of a configuration change.

LogTime

Indicates the time when the configuration changes.

CfgBaselineTime

Indicates the time when the baseline version is configured.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.6.10.1.1.7.1.3

hwCfgLogSrcCmd

hwCfgLogIndex

1.3.6.1.4.1.2011.6.10.1.1.7.1.4

hwCfgLogSrcData

hwCfgLogIndex

1.3.6.1.4.1.2011.6.10.1.1.7.1.5

hwCfgLogDesData

hwCfgLogIndex

1.3.6.1.4.1.2011.6.10.1.1.7.1.7

hwCfgLogTerminalUser

hwCfgLogIndex

1.3.6.1.4.1.2011.6.10.1.1.7.1.10

hwCfgLogCmdSrcAddress

hwCfgLogIndex

1.3.6.1.4.1.2011.6.10.1.1.7.1.15

hwCfgLogConfigChangeId

hwCfgLogIndex

1.3.6.1.4.1.2011.6.10.1.1.7.1.2

hwCfgLogTime

hwCfgLogIndex

1.3.6.1.4.1.2011.6.10.1.1.7.1.16

hwCfgLogCfgBaselineTime

hwCfgLogIndex

Impact on the System

Services are not affected.

Possible Causes

This trap was triggered when you specify the configuration file to be used at the next system startup, save the current configuration file, and clear the configuration file to be activated at the next system startup.

Procedure

  • This alarm message indicates a normal situation, and no action is required.