Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MSTP_1.3.6.1.4.1.2011.5.25.42.4.2.29 hwMstpProRootResume

MSTP_1.3.6.1.4.1.2011.5.25.42.4.2.29 hwMstpProRootResume

Description

The bridge resumes the position of root bridge. (ProcessID=[ProcessID], InstanceID=[InstanceID], ProInstRootType=[ProInstRootType])

A device resumed its root bridge role.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwMstpProRootResume

Trap OID

1.3.6.1.4.1.2011.5.25.42.4.2.29

Alarm ID

0x0d542002

Alarm Type

communicationsAlarm

Raise or Clear

Clear

Match trap

MSTP_1.3.6.1.4.1.2011.5.25.42.4.2.28 hwMstpProRootLost

Parameters

Name

Description

ProcessID

MSTP process ID

InstanceID

Multiple spanning tree instance (MSTI) ID

ProInstRootType

Type of root bridge

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.42.4.1.28.1.6

hwMstpProInstanceRootType

hwMstpProID

hwMstpInstanceID

Impact on the System

Services will not be affected.

Possible Causes

Cause 1: The smallest bridge ID of the newly added device was changed to be not the smallest.

Cause 2: The priority of an existing device on the network or device configurations in a multiple spanning tree region (MSTR) recovered.

Procedure

  • This trap message is informational only, and no action is required.