Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFMCOMM_1.3.6.1.6.3.1.1.5.4 linkup

IFMCOMM_1.3.6.1.6.3.1.1.5.4 linkup

Description

The interface status changes. (ifName=[ifName], AdminStatus=[ifAdminStatus], OperStatus=[ifOperStatus], Reason=[Reason], mainIfname=[mainIf])

The interface status changes.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

linkup

Trap OID

1.3.6.1.6.3.1.1.5.4

Alarm ID

0x08520003

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

IFNET_1.3.6.1.6.3.1.1.5.3 linkDown

Parameters

Parameter

Description

ifName

Interface name

AdminStatus

Configured interface status

OperStatus

Current interface status

Reason

Reason for trap generation

mainIfname

Name of the main interface

VB

VB OID

VB Name

VB Index

1.3.6.1.2.1.2.2.1.1

ifIndex

ifIndex

1.3.6.1.2.1.2.2.1.2

ifDescr

ifIndex

1.3.6.1.2.1.2.2.1.7

ifAdminStatus

ifIndex

1.3.6.1.2.1.2.2.1.8

ifOperStatus

ifIndex

Impact on the System

Traffic will be recovered.

Possible Causes

Cause 19: The link protocol is up.

Cause 21: Interface physical link is up.

Cause 23: The conditions for the activation of the interface are met.

Cause 24: The tunnel is up.

Cause 27: BFD session is up.

Cause 28: EFM UP.

Cause 31: DLDP detect up.

Cause 33: VRRP FLOW UP.

Cause 38: CRC ERR UP.

Cause 49: CFM UP.

Cause 51: The sub-interface linkDown alarm is disabled.

Procedure

  • This alarm message is informational only, and no action is required.