Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.31 hwFabricLinkLimitAlarmResume

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.31 hwFabricLinkLimitAlarmResume

Description

The number of current fabric links is equal to or larger than the number of fabric links configured. (hwStackFabricPort=[hwStackFabricPort], hwFabricCurrentLinkNum=[hwFabricCurrentLinkNum], hwFabricConfiguredLinkNum=[hwFabricConfiguredLinkNum])

The number of available fabric port links is larger than or equal to the configured alarm threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricLinkLimitAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.31

Alarm ID

0x09da2003

Alarm Type

equipmentAlarm

Raise or Clear

Clear

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.30 hwFabricLinkLimitAlarm

Parameters

Name Meaning

hwStackFabricPort

Indicates the fabric port number.

hwFabricCurrentLinkNum

Indicates the number of current links.

hwFabricConfiguredLinkNum

Indicates the configured alarm threshold.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.15

hwFabricCurrentLinkNum

N/A

1.3.6.1.4.1.2011.5.25.183.1.27.1.5 hwFabricConfiguredLinkNum

hwFabricPortIndex

Impact on the System

The downlink service port of the leaf switch connected to the fabric port restores to the normal state.

Possible Causes

Cause 1: The port and link recover from a fault.

Cause 2: The number of available links is increased or the alarm threshold is adjusted to be smaller than or equal to the number of current links.

Procedure

  1. This trap is informational only, and no action is required.