Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SYSTEM_1.3.6.1.4.1.2011.5.25.19.2.9 hwSysSlaveSwitchFailNotification

SYSTEM_1.3.6.1.4.1.2011.5.25.19.2.9 hwSysSlaveSwitchFailNotification

Description

Failed to run slave switch with SlvSwitchIndex [SlvSwitchIndex], ChassisNum[ChassisNum].

A master/slave main control board switchover failed.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Critical

Mnemonic Code

hwSysSlaveSwitchFailNotification

Trap OID

1.3.6.1.4.1.2011.5.25.19.2.9

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

[SlvSwitchIndex]

Index of a master/slave main control board switchover

[ChassisNum]

Number of a chassis on which a master/slave main control board switchover is performed

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.19.1.3.7.1.2

hwSysSlaveSwitchChassisNum

hwSysSlaveSwitchIndex

Impact on the System

User services may be interrupted.

Possible Causes

The slave switch is Up.

Procedure

  • Check wether the slave switch is Up.

    • If the slave switch is Up, go to step 3.
    • If the slave switch is not Up, go to step 2.

  • Install the slave switch and perform a master/slave switchover. Check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 4.

    • If the alarm persists, go to Step 3.

  • Collect trap, log, and configuration information, and contact technical support personnel.
  • End.