Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.14 hwBrdTempAlarmResume

DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.14 hwBrdTempAlarmResume

Description

The alarm indicating that the board temperature exceeded the upper alarm threshold was cleared.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityThresholdType=[EntityThresholdType], EntityThresholdCritical=[EntityThresholdCritical], EntityThresholdCurrent=[EntityThresholdCurrent], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

The board or card temperature fell below the upper threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwBrdTempAlarmResume

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.10.14

Alarm ID

0x0813000d

Alarm Type

environmentalAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm

Parameters

Name Meaning

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityThresholdType

Indicates the threshold type of the entity.

EntityThresholdCritical

Indicates the temperature threshold of the entity.

EntityThresholdCurrent

Indicates the current temperature.

EntityTrapFaultID

Indicates the error code.
  • 143617
  • 143616

Reason

Indicates a possible cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.1 hwEntityThresholdType entPhysicalIndex
1.3.6.1.4.1.2011.5.25.219.1.5.1.5 hwEntityThresholdWarning entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.5.1.3

hwEntityThresholdCurrent

entPhysicalIndex
1.3.6.1.4.1.2011.5.25.219.1.3 hwEntityTrapFaultID

N/A

Impact on the System

The board or card temperature is within the allowed range.

Possible Causes

The board or card temperature fell below the upper threshold. When the temperature is more than 3°C lower than the upper threshold, the high temperature alarm will be cleared.

Procedure

  1. This trap message is informational only, and no action is required.
Translation