Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.1 hwClockSourceSwitch

CLKM_1.3.6.1.4.1.2011.5.25.186.1.8.1 hwClockSourceSwitch

Description

Clock source switch notification.(hwClockChassisId = [hwClockChassisId], hwClockPllId = [hwClockPllId], hwClockLastSourceName = [hwClockLastSourceName],hwClockCurSourceName = [hwClockCurSourceName], hwClockSrcSelChassisIndex = [hwClockSrcSelChassisIndex], hwClockSrcSelType = [hwClockSrcSelType],hwClockSrcSelMode = [hwClockSrcSelMode])

The clock source changed.

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwClockSourceSwitch

Trap OID

1.3.6.1.4.1.2011.5.25.186.1.8.1

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Description

hwClockSrcSelChassisIndex

Index of the chassis where the clock source resides.

hwClockSrcSelType

Clock source type:

  • 1:System

hwClockChassisId

ID of the chassis where the clock source resides.

hwClockPllId

Clock source type ID.

hwClockLastSourceName

Last clock source name.

hwClockCurSourceName

Current clock source name.

hwClockSrcSelMode

Clock source selection mode:

  • auto(0): automatic clock source selection
  • manual(1): manual clock source selection
  • force(2): forcible clock source selection

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.186.1.7.4

hwClockChassisId

N/A

1.3.6.1.4.1.2011.5.25.186.1.7.6

hwClockPllId

N/A

1.3.6.1.4.1.2011.5.25.186.1.7.1

hwClockLastSourceName

N/A

1.3.6.1.4.1.2011.5.25.186.1.7.2

hwClockCurSourceName

N/A

1.3.6.1.4.1.2011.5.25.186.1.10.1.3

hwClockSrcSelMode

hwClockSrcSelChassisIndex

hwClockSrcSelType

Impact on the System

  • If the clock source becomes an empty source, the clock signal accuracy will degrade.

  • If the new clock source provides clock signals of better quality, services will not be affected.

  • If the new clock source provides clock signals of lower quality, the clock signal accuracy will degrade.

Possible Causes

1: Attributes of a clock device on the network were changed, which caused the switchover of the master clock.

2: An associated link failed or an associated interface became Down, which caused the switchover of the master clock.

3: The clock source was manually switched during manual or forcible clock source selection.

Procedure

  1. Run the display clock config command to check the operating mode of the clock source.

    • If the operating mode is free, the clock source is in free state. Go to step 6.

    • If the operating mode is hold, the clock source is in hold state. Go to step 6.

    • If the operating mode is normal, go to step 2.

  2. Run the display clock config command to check the clock source selection mode.

    • If the clock source selection mode is manual or force, the clock source is switched forcibly. Go to step 6.

    • If the clock source selection mode is automatic, go to step 3.

  3. Run the display clock source command to check whether the clock source is in normal state.

    • If so, go to step 4.

    • If not, go to step 5.

  4. Check whether attributes of the clock source are changed.

    • If so, go to step 6.

    • If not, go to step 5.

  5. Collect alarm information, log information, and configuration of the device, and contact technical support.
  6. End.
Translation