Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ND_1.3.6.1.4.1.2011.5.25.332.2.2 hwSlotNDThresholdResumeAlarm

ND_1.3.6.1.4.1.2011.5.25.332.2.2 hwSlotNDThresholdResumeAlarm

Description

The number of ND entries was restored to the threshold of slot. (entPhysicalIndex=[entPhysicalIndex], Slotname=[slotname], Threshold=[Threshold], Number of dynamic ND entries=[DynEntries], Number of static ND entries=[StatEntries]).

The number of ND entries on a board fell below the 70% of alarm threshold.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwSlotNDThresholdResumeAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.332.2.2

Alarm ID

0x00f10041

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Clear

Match trap

ND_1.3.6.1.4.1.2011.5.25.332.2.1_hwSlotNDThresholdExceedAlarm

Parameters

Parameter Description

entPhysicalIndex

Index of the board that reports the clear alarm

Slotname

Name of the board that reports the clear alarm

Threshold

Clear alarm threshold

Number of dynamic ND entries

Number of dynamic ND entries on the board that reports the clear alarm

Number of static ND entries

Number of static ND entries on the board that reports the clear alarm

VB

VB OID

VB Name

VB Index

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.332.1.1.1.3

hwNDSlotThresholdResumeValue

hwNDSlotPhysicalIndex

1.3.6.1.4.1.2011.5.25.332.1.1.1.4

hwNDSlotDynamicNumber

hwNDSlotPhysicalIndex

1.3.6.1.4.1.2011.5.25.332.1.1.1.5

hwNDSlotStaticNumber

hwNDSlotPhysicalIndex

Impact on the System

None

Possible Causes

Dynamic ND entries aged, or ND entries were manually deleted from the board.

Procedure

  • This trap message is informational only, and no action is required.