Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.22 hwStackMemberLimit

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.22 hwStackMemberLimit

Description

The number of stack members has reached the upper limit and new members failed to join. (hwStackMemberThreshold=[hwStackMemberThreshold])

The number of stack members has reached the upper limit and new members failed to join.

Attribute

Attribute

Description

Alarm or Event

Event

Trap Severity

Warning

Mnemonic Code

hwStackMemberLimit

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.22

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Meaning

hwStackMemberThreshold

Maximum number of stack members.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.9

hwStackMemberThreshold

N/A

Impact on the System

Some devices cannot join the stack system.

Possible Causes

The number of stack members reaches the upper limit.

Procedure

  1. Check whether the stack members join or are merged due to incorrect connections.

    • If yes, reconnect the links.

    • If no, remove excess stack member devices.