Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ND_1.3.6.1.4.1.2011.5.25.332.2.3 hwInterfaceNDThresholdExceedAlarm

ND_1.3.6.1.4.1.2011.5.25.332.2.3 hwInterfaceNDThresholdExceedAlarm

Description

The number of ND entries exceeded the threshold of interface. (entPhysicalIndex=[entPhysicalIndex], Slotname=[slotname], InterfaceName=[InterfaceName], Threshold=[Threshold], Number of dynamic ND entries=[DynEntries], Number of static ND entries=[StatEntries]).

The number of ND entries on an interface exceeded the 80% of alarm threshold.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwInterfaceNDThresholdExceedAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.332.2.3

Alarm ID

0x00f10043

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

ND_1.3.6.1.4.1.2011.5.25.332.2.4_hwInterfaceNDThresholdResumeAlarm

Parameters

Parameter Description

entPhysicalIndex

Index of the board that reports the alarm

Slotname

Name of the board that reports the alarm

InterfaceName

Name of the interface that reports the alarm

Threshold

Alarm threshold

Number of dynamic ND entries

Number of dynamic ND entries on the interface that reports the alarm

Number of static ND entries

Number of static ND entries on the interface that reports the alarm

VB

VB OID

VB Name

VB Index

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.2.1.2.2.1.2

ifDescr

ifIndex

1.3.6.1.4.1.2011.5.25.332.1.2.1.2

hwNDIntfThresholdExceedValue

hwNDIntfIndex

1.3.6.1.4.1.2011.5.25.332.1.2.1.4

hwNDIntfDynamicNumber

hwNDIntfIndex

1.3.6.1.4.1.2011.5.25.332.1.2.1.5

hwNDIntfStaticNumber

hwNDIntfIndex

Impact on the System

The interface cannot learn more ND entries.

Possible Causes

Many services were deployed, triggering the interface to learn a large number of dynamic ND entries. Or, a large number of static ND entries were configured on the interface.

Procedure

  • Collect trap, log, and configuration information, and contact technical support personnel.