Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DRIVER_1.3.6.1.4.1.2011.5.25.219.2.10.25 hwEntityDyingGaspEvent

DRIVER_1.3.6.1.4.1.2011.5.25.219.2.10.25 hwEntityDyingGaspEvent

Description

Power supply failed.([SystemMacAddress], [Reason])

The power supply is abnormal

Attributes

Attribute

Description

Alarm or Event

Event

Trap Severity

Alert

Mnemonic Code

hwEntityDyingGaspEvent

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.10.25

Alarm ID

This is an event trap and does not involve alarm ID.

Alarm Type

This is an event trap and does not involve alarm type.

Raise or Clear

This is an event trap and does not involve alarm generation or clearance.

Match trap

This is an event trap and does not involve the matching trap.

Parameters

Parameter Meaning

SystemMacAddress

System MAC address.

Reason

Reason.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.12

hwEntityTrapRelativeResource

N/A

1.3.6.1.4.1.2011.5.25.219.1.13

hwEntityTrapReasonDescr

N/A

Impact on the System

The device is powered off or restarted.

NOTE:

This event may trigger two alarms of the same content.

Possible Causes

  • The power cable is loose.

  • The external power cable is faulty.

  • The power module is faulty.

Procedure

  1. Check whether the power cable is loose.

    • If so, insert the power cable tightly.

    • If not, go to step 2.

  2. Check whether external power supply is normal.

    • If so, go to step 3.

    • If not, solve the external power supply problem.

  3. Check whether the power module is faulty.

    • If so, replace the power module.

    • If not, go to step 4.

  4. Collect alarms, logs, and configurations, and contact technical support personnel.