Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.9 hwOpticalUnAuthorized

DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.9 hwOpticalUnAuthorized

Description

The optical module was not certified by Huawei Ethernet Switch.(EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=[EntityTrapFaultID], Reason=[Reason])

An optical module that is not certified for Huawei Ethernet switches was installed.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwOpticalUnAuthorized

Trap OID

1.3.6.1.4.1.2011.5.25.219.2.4.9

Alarm ID

0x08132154

Alarm Type

processingErrorAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.219.2.4.10 hwOpticalUnAuthorizedResume

Parameters

Parameter Description

EntPhysicalIndex

Indicates the index of an entity.

EntPhysicalName

Indicates the name of an entity.

EntityTrapFaultID

Indicates the error code. The error code in this alarm is 145920.

Reason

Indicates the alarm cause.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.219.1.1

hwEntityPhysicalIndex

N/A

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.219.1.3

hwEntityTrapFaultID

N/A

Impact on the System

Check whether the optical module was delivered early by Huawei. If so, the system is not affected. If not, the optical module may work abnormally, causing service interruption.

Possible Causes

An optical module that is not certified for Huawei Ethernet switches was installed. Alarms may be generated because vendor information of Huawei early delivered optical modules is not recorded.

Procedure

  • If the optical module was delivered early by Huawei, run the transceiver non-certified-alarm disable command to disable the alarm function for optical modules that are not certified for Huawei Ethernet switches.

    NOTE:

    In versions earlier than V200R001C00, after the alarm function is disabled, the generated alarms will not be automatically cleared. To clear these alarms, remove and then install the optical module.

  • If the optical module is not delivered by Huawei or not certified for Huawei Ethernet switches, replace it with one that is certified for Huawei Ethernet switches.
Translation