No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.30 hwFabricLinkLimitAlarm

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.30 hwFabricLinkLimitAlarm

Description

The number of current fabric links is smaller than the number of fabric links configured. (hwStackFabricPort=[hwStackFabricPort], hwFabricCurrentLinkNum=[hwFabricCurrentLinkNum], hwFabricConfiguredLinkNum=[hwFabricConfiguredLinkNum])

The number of available fabric port links is smaller than the configured alarm threshold.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwFabricLinkLimitAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.183.1.22.30

Alarm ID

0x09da2003

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

STACKMNG_1.3.6.1.4.1.2011.5.25.183.1.22.31 hwFabricLinkLimitAlarmResume

Parameters

Name Meaning

hwStackFabricPort

Indicates the fabric port number.

hwFabricCurrentLinkNum

Indicates the number of current links.

hwFabricConfiguredLinkNum

Indicates the configured alarm threshold.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.183.1.32.8

hwStackFabricPort

N/A

1.3.6.1.4.1.2011.5.25.183.1.32.15

hwFabricCurrentLinkNum

N/A

1.3.6.1.4.1.2011.5.25.183.1.27.1.5 hwFabricConfiguredLinkNum

hwFabricPortIndex

Impact on the System

The downlink service port of the leaf switch connected to the fabric port will enter the error-down state.

Possible Causes

Cause 1: The networking is improper or the configured alarm threshold for the number of available fabric port links is high.

Cause 2: The protocol state of the port is Down.

Cause 3: The fabric port link is faulty.

Procedure

  1. Run the display stack link-state last-down-reason command to check whether a fabric port link is Down.

    • If a fabric port link is Down, rectify the fault according to the reason.
    • If all fabric port links are Up, go to step 2.

  2. Increase the number of fabric port links or run the fabric min-links threshold alarm-threshold command to reduce the alarm threshold for the number of available fabric port links.