Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.73 hwXQoSPfcTurnOffAlarm

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.73 hwXQoSPfcTurnOffAlarm

Description

PFC was disabled because the threshold for the number of detected deadlocks was exceeded. (interface = [], lossless priority = [], number of detected deadlocks = [], threshold = [].)

PFC is disabled automatically when the deadlock count reaches the threshold.

Trap Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwXQoSPfcTurnOffAlarm

Trap OID

1.3.6.1.4.1.2011.5.25.32.4.1.11.73

Alarm ID

0x09622024

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Raise

Match trap

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.74 hwXQoSPfcTurnOffResume

Parameters

Name Meaning

hwXQoSPfcTurnOffAlarmIfName

Indicates the interface name.

hwXQoSPfcTurnOffAlarmPriority

Indicates the priority.

hwXQoSPfcTurnOffAlarmDetectedNumber

Indicates the detected deadlock count.

hwXQoSPfcTurnOffAlarmThreshold

Specifies the threshold for the deadlock count within 1 minute. PFC is disabled automatically after the threshold is exceeded.

VB Parameters

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.32.4.1.49.1.1.1

hwXQoSPfcTurnOffAlarmIfName

hwXQoSPfcTurnOffAlarmIfName

hwXQoSPfcTurnOffAlarmPriority

hwXQoSPfcTurnOffAlarmDetectedNumber

hwXQoSPfcTurnOffAlarmThreshold

1.3.6.1.4.1.2011.5.25.32.4.1.49.1.1.2

hwXQoSPfcTurnOffAlarmPriority

hwXQoSPfcTurnOffAlarmIfName

hwXQoSPfcTurnOffAlarmPriority

hwXQoSPfcTurnOffAlarmDetectedNumber

hwXQoSPfcTurnOffAlarmThreshold

1.3.6.1.4.1.2011.5.25.32.4.1.49.1.1.3

hwXQoSPfcTurnOffAlarmDetectedNumber

hwXQoSPfcTurnOffAlarmIfName

hwXQoSPfcTurnOffAlarmPriority

hwXQoSPfcTurnOffAlarmDetectedNumber

hwXQoSPfcTurnOffAlarmThreshold

1.3.6.1.4.1.2011.5.25.32.4.1.49.1.1.4

hwXQoSPfcTurnOffAlarmThreshold

hwXQoSPfcTurnOffAlarmIfName

hwXQoSPfcTurnOffAlarmPriority

hwXQoSPfcTurnOffAlarmDetectedNumber

hwXQoSPfcTurnOffAlarmThreshold

Impact on the System

PFC is disabled automatically.

Possible Causes

The deadlock count within 1 minute exceeds the threshold for automatic disabling of PFC.

Procedure

  1. Manually disable PFC.