Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.22 hwXQOSQueueBufferOverrunResume

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.22 hwXQOSQueueBufferOverrunResume

Description

The used buffer of queue is recovered from overrun(QueueID = [hwXQOSQueueBufferAlarmQueueID], interface = [hwXQOSQueueBufferAlarmIfName], slot =[hwXQOSQueueBufferAlarmSlotStr]).

The queue buffer is restored.

Attribute

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Error

Mnemonic Code

hwXQOSQueueBufferOverrunResume

Trap OID

1.3.6.1.4.1.2011.5.25.32.4.1.11.22

Alarm ID

0x09622003 (0d157425667)

Alarm Type

qualityOfServiceAlarm

Raise or Clear

Clear

Match trap

QOS_1.3.6.1.4.1.2011.5.25.32.4.1.11.21 hwXQOSQueueBufferOverrunAlarm

Parameters

Parameter Meaning

hwXQOSQueueBufferAlarmQueueID

Number of the queue that is congested.

hwXQOSQueueBufferAlarmIfName

Name of the interface where congestion occurs.

hwXQOSQueueBufferAlarmSlotStr

Name of the uplink card where congestion occurs.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.32.4.1.20.3.1.1

hwXQOSQueueBufferAlarmChassisID

hwXQOSQueueBufferAlarmChassisID

hwXQOSQueueBufferAlarmSlotID

hwXQOSQueueBufferAlarmIfIndex

hwXQOSQueueBufferAlarmQueueID

1.3.6.1.4.1.2011.5.25.32.4.1.20.3.1.2

hwXQOSQueueBufferAlarmSlotID

hwXQOSQueueBufferAlarmChassisID

hwXQOSQueueBufferAlarmSlotID

hwXQOSQueueBufferAlarmIfIndex

hwXQOSQueueBufferAlarmQueueID

1.3.6.1.4.1.2011.5.25.32.4.1.20.3.1.3

hwXQOSQueueBufferAlarmIfIndex

hwXQOSQueueBufferAlarmChassisID

hwXQOSQueueBufferAlarmSlotID

hwXQOSQueueBufferAlarmIfIndex

hwXQOSQueueBufferAlarmQueueID

1.3.6.1.4.1.2011.5.25.32.4.1.20.3.1.4

hwXQOSQueueBufferAlarmQueueID

hwXQOSQueueBufferAlarmChassisID

hwXQOSQueueBufferAlarmSlotID

hwXQOSQueueBufferAlarmIfIndex

hwXQOSQueueBufferAlarmQueueID

Impact on the System

Services will not be affected.

Possible Causes

The queue buffer is restored.

Procedure

  1. This message is informational only and no action is required.
Translation