Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LACP_1.3.6.1.4.1.2011.5.25.41.3.4 hwLacpPartialLinkLoss

LACP_1.3.6.1.4.1.2011.5.25.41.3.4 hwLacpPartialLinkLoss

Description

Link bandwidth lost partly. (TrunkIndex=[TrunkIndex], TrunkIfIndex=[TrunkIfIndex], TrunkId=[TrunkId], TrunkName=[TrunkName], Reason=[Reason])

Part of the bandwidth of a link was lost.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Critical

Mnemonic Code

hwLacpPartialLinkLoss

Trap OID

1.3.6.1.4.1.2011.5.25.41.3.4

Alarm ID

0x09360002

Alarm Type

communicationsAlarm

Raise or Clear

Raise

Match trap

LACP_1.3.6.1.4.1.2011.5.25.41.3.15 hwLacpPartialLinkLossResume

Parameters

Parameter Description

TrunkIndex

Index of a trunk

TrunkIfIndex

Index of a trunk interface

TrunkId

ID of a trunk interface

TrunkName

Name of a trunk interface

Reason

indicates the cause for.

Reason why part of the bandwidth of a link was lost

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.41.1.3.3.1.2

hwTrunkIfID

hwTrunkIndex

1.3.6.1.2.1.31.1.1.1.1

ifName

ifIndex

Impact on the System

Part of services were interrupted.

Possible Causes

Cause: The number of the Eth-Trunk member links that were Up was smaller than the lower threshold value that was set, which caused the LAG to become Down. As a result, a PLL trap was generated.

Procedure

  1. Run the display interface brief command to check whether the interface is Down.

    • If so, go to Step 2.
    • If not, go to Step 4.

  2. Run the undo shutdown command to check whether the alarm is cleared.

    • If so, go to Step 10.
    • If not, go to Step 3.

  3. Check whether the physical link is faulty.

    • If so, go to Step 7.
    • If not, go to Step 4.

  4. Run the display eth-trunk [ trunk-id [ interface interface-type interface-number | verbose ] ] command to check whether there are member interfaces in the LAG.

    • If so, go to Step 5.
    • If not, go to Step 8.

  5. Run the display trunkmembership eth-trunk trunk-id command to check whether the lower threshold for Eth-Trunk member links is set in the LAG; whether the number of Eth-Trunk member links that are successfully negotiated is smaller than the lower threshold for the Eth-Trunk member links that can be Up.

    • If so, go to Step 6.
    • If not, go to Step 9.

  6. In the Eth-Trunk interface view, run the least active-linknumber link-number command to correctly set the lower threshold of Trunk member links that can be Up. Then, check whether the alarm is cleared.

    • If so, go to Step 10.
    • If not, go to Step 9.

  7. Repair the physical link and then check whether the alarm is cleared.

    • If so, go to Step 10.
    • If not, go to Step 4.

  8. Run the eth-trunk trunk-id command in the interface view and add the current Ethernet interface to the Eth-Trunk interface as required. Then, check whether the alarm is cleared.

    • If so, go to Step 10.
    • If not, go to Step 5.

  9. Collect information about configurations, trap messages, and log messages, and then contact technical support personnel.
  10. End.