Alarm Handling

CloudEngine 8800, 7800, 6800, and 5800 V200R005C10

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PTP_1.3.6.1.4.1.2011.5.25.187.5.19 hwPtpExtTimePortLost

PTP_1.3.6.1.4.1.2011.5.25.187.5.19 hwPtpExtTimePortLost

Description

The external Time Port status changed.(Status = [Status], ExternalTimePort = [ExternalTimePort])

The external time source was lost.

Attributes

Attribute

Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwPtpExtTimePortLost

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.19

Alarm ID

0x09af000d

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PTP_1.3.6.1.4.1.2011.5.25.187.5.20_hwPtpFrequencyLockResume

Parameters

Parameter Description

Status

Port status of the external time source:

  • 1: normal(0)

  • 2: portDown(1)

ExternalTimePort

Port name of the external time source:

  • 1: bits0(0)

  • 2: bits1(1)

  • 3: bits2(2)

  • 4:bits1slot4(1025)

  • 5:bits1slot5(1281)

  • 6:bits1slot6(1537)

  • 7:bits1slot7(1793)

  • 8:bitts1slot11(2817)

  • 9:bits1slot12(3073)

  • 10:bits1slot19(4865)

  • 11:bits1slot20(5121)

  • 12:bits1slot21(5377)

  • 13:bits1slot22(5633)

This parameter can be converted to a 2-byte hexadecimal number. The low byte indicates the BITS clock type, and the high byte indicates the MPU slot ID of the BITS clock.

For example, the parameter 769 can be converted to a 2-byte hexadecimal number 0x0301. The low byte 01 indicates the BITS1 clock, and the high byte 03 indicates the MPU slot ID 3 of the BITS1 clock.

VB

VB OID

VB Name

VB Index

1.3.6.1.4.1.2011.5.25.187.1.89

hwPtpExtTimePortStatus

N/A

1.3.6.1.4.1.2011.5.25.187.1.90

hwPtpExtTimePortType

N/A

Impact on the System

Frequency synchronization or time synchronization cannot be performed with the external time source.

Possible Causes

The connection between the external time source and the local device was closed.

Procedure

  1. Run the display interface interface-type interface-name command to check whether the status of the interface connecting the device to the external time source is Up.

    • If so, go to step 2.

    • If not, troubleshoot the fault.

  2. Collect alarm information, log information, and configuration of the device, and contact technical support.
  3. End.